线程阻塞,从堵了一个开始就会慢慢的积累,直到down机。看下日志,从什么功能出现的问题,具体到哪个方法,优化下语句;再就是调节参数,将max再往上调
In the WebLogic Console logs one can see the error below. Symtom{STUCK_THREADS,HIGH,ThreadPoolRuntime,ThreadPool has stuck threads} Error log from stdout.log "[STUCK]ExecuteThread: '1' for queue: 'weblogic.kernel.Default (self-tuning)'" #29 daemon prio=1 os_prio=0 tid=0x00007f0945865000...
weblogic 10后台出现警告,原因:ThreadPool has stuck threads 在WEBLOGIC中如果一个线程执行时间超过了Stuck Thread Max Time规定的时间, WEBLOGIC会把它认为是STUCK线程,并记录在日志中。 我们也可以通过'Dump Thread Stacks' 来捕获STUCK状态的进程。 Home > Summary of Servers > AdminServer>Monitoring>Performance>'...
at weblogic.work.ThreadPoolRuntimeMBeanImpl.getStuckExecuteThreads(ThreadPoolRuntimeMBeanImpl.java:100) Truncated. see log file for complete stacktrace > 修改weblogic中的StuckThreadMaxTime参数:登录weblogic的控制台——环境(Environment)——服务器(Servers),点击AdminServer(admin)——配置(Configuration)——优...
Following are the stack trace of stuck threads: "Http Request Information: weblogic.servlet.internal.ServletRequestImpl@565da955[POST /Agile/FSHelper/FSHelperWSService] ", which is more than the configured time (StuckThreadMaxTime) of "1,200" seconds in "server-failure-trigger". Stack trace: ...
Stuck Thread Max Time-- Amount of time, in seconds, that a thread must be continually working before a server instance diagnoses a thread as being stuck. Stuck Thread Timer Interval-- Amount of time, in seconds, after which a server instance periodically scans threads to see if they have ...
nidis the OS-level native thread identifier. It can be used effectively to correlate with high CPU usage threads identified at the OS level (e.g. with Linuxwatchcommand). SeeUnexpected High CPU Usage with WebLogic Server (WLS) Support Pattern (Doc ID 779349.1)for detailed steps. ...
Stuck threads are being observed in the WebCenter Portal/Spaces Managed Server logs. Some of the stuck threads look like these: [STUCK] ExecuteThread: '37' for queue: 'weblogic.kernel.Default (self-tuning)'" id=<ID> idx=<IDX> tid=<TID> prio=1 alive, blocked, native_blocked, daemon ...
The number of seconds after which WebLogic Server periodically scans threads to see if they have been continually working for the configured maximum length of time. Privileges: Read/Write Default Value: 60 Minimum value: 0 Maximum value: 2147483647 Redeploy or R...
Stuck Threads Waiting to Access WeakHashMap Object Applies to: Oracle WebLogic Portal - Version: 9.2.0 to 10.3.1.0.2 - Release: Weblogic Platform to Information in this document applies to any platform. Symptoms When P13N cache is configured in 职场 休闲 WeakHashMap stuck 转载 精选 kaka...