The impact of this practice on the long-term serviceability performance of the primary structure is not clear and could be an important consideration deserving further analysis. This paper presents a case study of an elevated water tank that was motivated by this particular consideration. The ...
www.nature.com/scientificreports OPEN Structural analysis of traditional Chinese complex puzzle locks Kan Shi1, Ming Jie Wang1,Yang Zhang2, Kuo Hung Hsiao3* &Yan An Yao4 The development of barbed-spring locks in ancient China has a history of more than 2000 years. ...
So I have decided to make underground water tank base slab as a footing for column. So I import etabs model to safe and just take uniform water load on base slab and point load from columns. This is the residential house. The BC is 2tsf. But SAFE is showing tension on the base slab...
SDC Verifier automates the application of the following loads: Buoyancy Load A water pressure acting on a construction (e.g. ship hull) including wave parameters. Tank Ballast Fluid level based on a mass content transferred into a pressure level on a tank surface. Wind Load Height dependent ...
Assessment of Ratcheting in SGDHR Pipe Bend based on Linear and Bi-linear Analysis Rosy Sarkar, Bhuwan Chandra Sati, R. Suresh Kumar Pages 75-92 View PDF Article preview select article Assessment on structural integrity of aluminium alloy AA6061 water tank used in satellite launch vehicles Researc...
Characteristics of strain-induced martensitic transformation in welded joints with the structure of metastable austenite Iu. Korobov, O. Pimenova, M. Filippov, M. Khadyev, ... N. Razikov Pages 34-43 View PDF Article preview select article Numerical Analysis and Effects on Rigidity of Combat Veh...
Mechanical properties and mechanism analysis The predesigned hydrogel integral synchronous assembly strategy is universal and scalable for building complex bioinspired structures, through which a structural material with a rigid cavity-wall structure was fabricated. Moreover, sandwich structural material (SSM)...
construction joints; reinforcement details; analysis and design; strength and serviceability; flexural and axial loads; shear and torsion; development and splices of reinforcement; slab systems; walls; footings; precast concrete; composite flexural members; prestressed concrete; shells and folded plate memb...
After finding the condition ranking of the existing structure, an analysis was carried out using SAP 2000 to find the present-day seismic requirements using IS codes. After knowing the seismic demand of the water tank, various retrofitting methods were adopted for improving the drift capacity and ...