Biaxial stressCombinationsCompressionCompressive strengthConcreteConcrete curingStressesTensionMeasurement of the strength of one concrete under conventional triaxial compression, "estension", and tension plus biaxial compression are described. The concrete specimens had a water/cement ratio of 0.47 and an ...
and Daudeville L., Ultimate strength of plain concrete under extreme combined stresses: triaxial and proportional stress paths, Laboratoire Sols, Solides, Structures, France, 2006.Gabet, T., Malecot, Y., Daudeville, L. 2006. Ultimate strength of plain concrete under extreme combined stresses :...
The strength of concrete under combined shear and direct stress THIRTY-NINE HOLLOW CYLINDERS, MADE OF FIVE DIFFERENT CONCRETE MIXES, WERE TESTED UNDER DIRECT COMPRESSION AND TORSION TO STUDY THE FAILURE OF CONCRETE UNDE... CD Goode,MA Helmy - 《Magazine of Concrete Research》 被引量: 36发表: ...
Strength of concrete under multiaxial stress states Past investigations of the multiaxial behavior and strength of concrete have used both a wide variety of different materials, and of different test methods. In order to isolate the effects of these two variables, seven institutions coope... K. Ge...
Sixteen CFT columns with different values of concrete compressive strength (fc) and L/D ratio were tested under concentric load in order to analyze the influence of these parameters on the general behavior and load capacity. The main geometric characteristics of the tested specimens were D=114.3mm...
A stressstrain model is developed for concrete subjected to uniaxial compressive loading and confined by transverse reinforcement. The concrete section may... J. Mander,M. Priestley,R Park 被引量: 1749发表: 1991年 A Study of the Failure of Concrete under Combined Compressive Stresses The investiga...
The volume of waste materials and by products are increasing and endangering the environment safety. Some of these waste materials can be used in the production of building materials, such as concrete. In order to study the possibility of using some wast
Therefore, it is difficult to satisfy the assumption of an internal stress balance when these test techniques are used to measure the dynamic strength of concrete under a high loading rate. At present, the dynamic tensile strength of concrete under a high strain rate is mostly measured by the ...
Further, the investigation was carried out to develop a HFRC made with metallic and non-metallic fibres at a total fibre dosage of 1%. Mechanical properties, namely compressive strength, direct tensile strength, flexural strength and stress-stain behaviour of concrete under uni-axial stresses were ...
Biaxial bending of slender HSC columns and tubes filled with concrete under short- and long-term loads:: I) Theory. An analytical method that calculates both the short- and long-term response of slender columns made of high-strength concrete (HSC) and tubes filled with c... RODRIGUEZ-GUTIERR...