查看属性语法:storcli64 /cx show <properties> 如查看蜂鸣器状态:strocli64 /c0 show alarm 设置某个属性语法:storcli64 /cx set <properties> 如设置蜂鸣器开启:storcli64 /cx set alarm=on 1.5物理磁盘 可查看磁盘的健康状态,对不健康的磁盘进行替换,设置磁盘状态,设置磁盘初始化,对磁盘进行定位 1.5.1 查看磁...
[root@localhost ~]# ./storcli64 show ctrlcount ---查看raid数量 Status Code=0Status=Success Description=None Controller Count=1[root@localhost~]# [root@localhost ~]# ./storcli64 /c0 /v0 show ---查看raid结构,虚拟硬盘 Controller=0Status=Success Description=None Virtual Drives :=== ---DG/...
c0 show all #查询0号控制器阵列信息 ./storcli64 /c0 /v0 show all #查询0号控制器0号卷信息 ./storcli64 /call /eall /sall show all #查看所有硬盘的详细信息 ./storcli64 /c0/e0/s23 start locate #开启/c0/e0/s23的硬盘灯 ./storcli64 /c0/e0/s23 stop locate #关闭/c0/e0/s23的硬盘...
查看磁盘状态:storcli64 /c0 /eall/sall show磁盘状态为UGOOD空闲盘,磁盘状态为DHS为专属热备,磁盘状态为GHS为全局热备 添加专属热备 获得dgs号storcli64 /call/vall show可看到DG及dgs的值为特定的DG配置热备 获取空闲磁盘storcli64 /c0 /eall/sall show磁盘状态为UGOOD c.语法storcli64 /cx/ex/sx add hots...
storcli64 show <properties> show 查看的基础命令,可以直接使用show,也可以在show后加参数all、alarm等 例如:storcli64 show all storcli64 set <properties> set 设置的基础命令,可以通过设置参数改变状态 例如:storcli64 /c0/e252/s0 set good storcli64 /c0/e252/s0 start locate ...
storcli64查看raid [root@localhost ~]# ./storcli64 show ctrlcount ---查看raid数量 Status Code = 0 Status = Success Description = None Controller Count = 1 [root@localhost ~]# [root@localhost ~]# ./storcli64 /c0 /v0 show ---查看raid结构,虚拟硬盘 Controller = 0 Status = Success...
storcli64 show all 查看帮助文档 storcli64 -h 1.4 控制器 查看属性语法:storcli64 /cx show <properties> 如查看蜂鸣器状态:strocli64 /c0 show alarm 设置某个属性语法:storcli64 /cx set <properties> 如设置蜂鸣器开启:storcli64 /cx set alarm=on ...
storcli64 show all 查看帮助文档 storcli64 -h 1.4 控制器 查看属性语法:storcli64 /cx show <properties> 如查看蜂鸣器状态:strocli64 /c0 show alarm 设置某个属性语法:storcli64 /cx set <properties> 如设置蜂鸣器开启:storcli64 /cx set alarm=on ...
/opt/MegaRAID/storcli/storcli64 /c0 /vall show all 显示第一块RAID卡上所有逻辑磁盘相关信息,也可指定某个逻辑磁盘v0,v1等等。 /opt/MegaRAID/storcli/storcli64 /c0/v0 show 显示第一块RAID卡上第一个逻辑磁盘信息 /opt/MegaRAID/storcli/storcli64 /c0/v0 del force 强制删除某个逻辑磁盘 ...
为了查询超级电容的相关信息,我们可以利用storcli64工具。首先,输入命令storcli64 /c0/cv show all,获取控制器状态。结果显示BBU型号为CVPM02,当前温度为28摄氏度,状态为最优。电池状态检查显示,无需更换电池且有足够空间用于缓存卸载。电池组能量为294焦耳,剩余容量为108%,预留的备用空间为0。设计...