1) steady-state fluorescence 稳态荧光法1. The measured results were in accordance with the results by other methods such as electronic conductivity and surface tension,therefore,steady-state fluorescence method was proved to be feasible as a method of measuring aggregation properties of anionic Gemini...
1) Steady-state fluorescence 稳态荧光测量 2) Stable State 稳态 1. Finite Element Simulation ofStable StateTemperature Field of Ladle; 钢包稳态温度场的有限元模拟 2. The phenomenon of glimmer is a repeated process of transition, and the stable state belongs to the stability of the balance point ...
Marangoni AG (1992) Steady-state fluorescence pola- rization spectroscopy as a tool to determine micro- viscosity and structural order in food systems. Food Res [nt 25,67-80Marangoni, A.G., 1992. Steady-state fluorescence polarization spectroscopy as a tool to determine micro viscosity and ...
1) Steady-state fluorescence quenching 稳态荧光猝灭2) fluorescence quenching 荧光猝灭 1. Determination of Hg~(2+) with rhodamine 6G by fluorescence quenching method; 罗丹明6G荧光猝灭法测定Hg~(2+)离子 2. Determination of trace Pb~(2+) by fluorescence quenching with Y_2O_3:Eu nanoparticles...
1.Critical micelle concentration (CMC), aggregation numbers and micropolarity of four sodium branched-alkyl benzene sulfonates were determined by steady-state fluorescence probe method in which pyrene was used as fluorescence probe and benzophenone was used as quencher.以芘为探针、二苯酮为猝灭剂,用稳...
Picosecond rotational diffusion in kinetic and steady state fluorescence spectroscopy The rotational diffusion time constants of tetrachlorotetraiodofluorescein in a series of low viscosity, hydrogen bonding solvents have been determined by ... G Porter,PJ Sadkowski,CJ Tredwell - 《Chemical Physics ...
A laboratory experiment using steady-state fluorescence polarization or anisotropy to determine the binding constant for a flavonoid–protein interaction is described. Using the intrinsic fluorescence of quercetin (a model flavonoid), the fluorescence anisotropy is measured as a function of human serum alb...
Steady-state measurements of fluorescence polarization have been widely adopted in the field of high-throughput screening for the study of biomolecular int... X Huang,A Aulabaugh - 《Methods in Molecular Biology》 被引量: 50发表: 2009年 Steady-State Fluorescence Anisotropy To Investigate Flavonoids...
The interaction of lipase from Candida cylindracea (CCL) with positively charged polymerizable surfactant vesicles was studied by the use of steady-state fluorescence techniques. The phase transition of vesicles composed of nonpolymerized and polymerized N-allylbis[2-(hexadecanoyloxy)ethyl]methylammonium br...
In a fluorescence-based MIP sensor system, it can be difficult to distinguish the analyte fluorescence from the fluorescence of the polymer itself. We studied steady-state fluorescence anisotropy of anthracene imprinted in a polymer (polyurethane) matrix. Vertically polarized excitation light was ...