Furthermore, the correlation between the (SpO2–SaO2) difference and PFI was assessed. The level of (dis)agreement was calculated for the three PFI categories separately. Overall, 281 patients and 1281 data points were analysed. There was a significant correlation between SaO2 and SpO2 (r = ...
For SpO2 values and SaO2 values, there was significant correlation between hematocrit (Hct), bilirubin level, arterial oxygen partial pressure (PaO2), arterial carbon dioxide partial pressure (PaCO2), arterial blood of acid-base level (PH), NTG use, and PGE1 use. For SpO2 values and SaO2 ...
Furthermore, the correlation between the (SpO2–SaO2) difference and PFI was assessed. The level of (dis)agreement was calculated for the three PFI ... M Thijssen,L Janssen,JL Noble,... - 《Journal of Clinical Monitoring & Computing》 被引量: 0发表: 2020年 Racial and ethnical discrepancy...
Correlation and concordance of SaO2/FiO2 and paO2/FiO2 ratios in patients with COVID-19 pneumonia who received non-invasive ventilation in two intensive care units 2024, Medicina Intensiva The Role of the Tissue Perfusion Index in Predicting Disease Severity and Prognosis in Patients with Severe and...
Correlation=0.98, P-value< 0.0001 Average reference oximeter Reference Heart Rate(ECG) Effective (SaO2) (ECG) [BPM] Comparison: Reference Pulse Oximeter Berry Pulse Oximeter 70 ~ 100 90 ~ 100 80 - < 90 67 - < 80 RESE≤3% Within the range...
Correlation=0.98, P-value< 0.0001 Average reference oximeter Reference Heart Rate(ECG) Effective (SaO2) (ECG) [BPM] Comparison: Reference Pulse Oximeter Berry Pulse Oximeter 70 ~ 100 90 ~ 100 80 - < 90 67 - < 80 RESE≤3% Within the range of 70~100%...
The correlation between SpO 2 and SaO 2 was studied using Pearson's correlation. The Bland–Altman plot was used to analyse the agreement between SpO 2 and SaO 2 . Furthermore, the correlation between the (SpO 2 –SaO 2 ) difference and PFI was assessed. The level of (dis)agreement ...
SaO2/FiO2Ventilación mecánicaObjective:To establish the correlation and validity between PaO2/FiO2 obtained on arterial gases versus noninvasive methods (linear, nonlinear, logarithmic imputation of PaO2/FiO2 and SpO2/FiO2) in patients under mechanical ventilation living at high altitude. Design:Ambi...
Correlation=0.98, P-value< 0.0001 Average reference oximeter Reference Heart Rate(ECG) Effective (SaO2) (ECG) [BPM] Comparison: Reference Pulse Oximeter Berry Pulse Oximeter 70 ~ 100 90 ~ 100 80 - < 90 67 - < 80 RESE≤3% Within the range of 70~100% #...