Spliced beamCFRPMFDRABAQUSSplice beams are considered a solution for accelerated bridge construction and a method for repairing damaged beams. One of the most challenging aspects of this technique is avoiding bond failure between the spliced members. In this study, ultrahigh performance concrete (UHPC...
Deterioration of Strength of RC Beams due to Corrosion and Its Influence on Beam Reliability This paper examines the effect of corrosion of reinforcing steel on flexural and shear strength, and subsequently on reliability, of reinforced concrete be... DV Val - 《Journal of Structural Engineering》...
et al. MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy. Nat. Methods 14, 331–332 (2017). Article CAS PubMed PubMed Central MATH Google Scholar Rohou, A. & Grigorieff, N. CTFFIND4: Fast and accurate defocus estimation from electron ...
3. RC beam test results The BFRP-RC beams were tested in flexure while inspecting the critical splice length and the bond behavior. The outcomes of the experimental testing were expressed in terms of mid-span deflections, strains in both BFRP bars and concrete, the load-carrying capacity, the...
The FRP profile assembled box beam is a box beam composed of pultruded cellular profiles that interlocking connected with other profiles through square tubes and toggle-bars. FRP型材拼装箱梁是由FRP拉挤型材空心板通过三向连接件、骨状挂钩等销接构件拼装而成的箱梁,具有重量轻、耐腐蚀性能好、施工速度...
Moreover, the maximum allowable weight constraint leads to an impossibility of placing stiffeners all along the length of the beam in all four corners. As such, a configuration has to be selected so that this fabricated/compound beam can be approximated as an integral I-beam. I have attached...
Steel–PSC hybrid beamPerfobond ribStudWe propose a suitable joint type for spliced hybrid I-girder bridges. The proposed joint is composed of multiple perfobond rib connectors attached in parallel to upper and lower plates. Three joint types including proposed joint type are tested on small-scale...
Specifications: Occasion: Professional Stage & DJ Voltage: AC100-240V, 50/60Hz Rated Power: 450W Light Source Type: 4 X100W COB LEDS, 50,000 hours Color Rendering Index: CRI≥Ra92 Color Temperature: 3200K/5600K or 3200K-5600K Features: |Beam Angle In Led|Light Out Show|Peaky Blinders...
In the UHSC beam tests, considerable bonding strength was identified in that the specimen with a lap-splice length of 10 d b exhibited flexural responses equivalent to those from the specimen without lap splices. In addition, the ductile failure was ensured when a moderate amount of steel ...
Here we describe the identification of a VZV latency-associated transcript (VLT), consistently detected in VZV and HSV-1 co-infected human TG that lies antisense to ORF61. Although multiple alternatively spliced transcripts are present during productive infection, the unique VLT isoform that supresse...