The red and green LEDs will flash once every 5 seconds for approximately 20 seconds until the power-up cycle is complete. Reinstall the detector housing onto the base. Test the smoke detector. Please refer to Testing the Smoke Detector below. Remove your system from Test Mode. Please refer ...
1427092 Photo-electric smoke detector LA DETECTION ELECTONIQUE FRANCAIS PROTECBAT 2 March 1973 [7 March 1972 26 May 1972] 10181/73 Heading G1A A photo-electric smoke detector which operates by detection of light scattered and absorbed by smoke in the detector chamber utilizes a solid state light...
Red, Green, Yellow light flash 1time alternately Low Battery Yellow light flashes 1 time Fault Yellow light flashes 3 times 1000cd LED helps escaping at the heavy smoke When the smoke detector alarms, the LED lights will illuminate automatically and ...
1.a tree,Cotinus obovatus,of the cashew family, native to the south central U.S., having egg-shaped leaves and large clusters of small white flowers. 2.a related shrub,C. coggygria,of Eurasia, having elliptical leaves and clusters of hairy, purple flowers. ...
Sadly at the moment, there's no one smart smoke detector that really stands out. Our favorite for a few years running has been the Nest Protect. It's the most full-featured alarm, blaring out a loud siren and telling you where the problem is. It will also send out a warning that it...
optical indication of the instrument’s condition. ORS142通过接至指示灯的三针及RZA142型号烟雾开关状态指示灯,以信号形式显示其功能状态,ORS142的有色LED灯对仪器的状态给出远程感光/视觉指示。If the ORS 142 is linked to an RSI smoke switch interface, detector status can be scanned from a ...
Product Name Fire Alarm Beam Smoke Detector Operating Voltage 20V to 28VDC Standby Current 23mA Alarm Current 33mA Commission Current 56mA Beam Pathway Length 8-100 meters Beam Path Angle ±0.4º Directional LED Indicator Guide Red: Fire ; Yellow: Fault ; Green: Alignment ...
Explosion Proof Infrared Beam Smoke Detector Operating Voltage 24VDC Standby Current ≤10mA Alarm Current ≤25mA Indicator Red, Green, Yellow LED Detection Distance 3-100m Detector Protective Diameter 14m Protected Area Ideal Maximum Is 100X14m ...
Detector dimensions (unit: mm) Note: Terminal S1 and S2 for connecting handheld programmer when setting parameters with it, or connecting to terminal D1 and D2 respectively when monitoring. As shown in the figure of the shell base. Use DIP switch (SW2) to set the parameter set you want ...
LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.The detector that initiated the alarm condition will have its red LED and relays latched until re...