SINGLE CHANNEL COCHLEAR IMPLANT ARTIFACT ATTENUATION IN LATE AUDITORY EVOKED POTENTIALSDisclosed herein are embodiments of methods and systems for attenuating artifacts in single channel cochlear implants. Both high and low frequency artifacts can be attenuating using embodiments of the disclosed methods and...
3. Our results so far suggest that patients deafened by are likely to obtain less benefit from a single channel cochlear implant than those deafened by other causes. Better results were also achieved by younger, more recently deafened patients and those who were good lipreaders. Despite the ...
Cochlear implantCombi 40+ReimplantationSpeech recognitionCochlear implantation has been performed for almost two decades at the Vienna University Hospital. Until 1994, single-channel implants were used (Ball-Electrode, SC6/2SC6, Vienna/Epoxy, Med-El, Innsbruck, Austria). The development of multi-...
Four cochlear implant subjects fitted with single‐channel sound processors identified consonants taken from a 23‐consonant set and spoken in a VCV context. The videotaped VCV items were presented in three conditions: lipreading alone, stimulation alone, and stimulation plus lipreading. The subjects...
These results confirm earlier studies indicating that high levels of open-set word recognition without visual cues can be obtained with the 3M/Vienna single-channel cochlear implant. (Arch Otolaryngol Head Neck Surg 1988;114:1123-1126) 展开 DOI: 10.1001/archotol.1988.01860220057023 被引量: 44 ...
Identifying Cochlear Implant Channels with Poor Electrode-Neuron Interface: Partial Tripolar, Single-Channel Thresholds and Psychophysical Tuning Curves: ErratumIdentifying Cochlear Implant Channels with Poor Electrode-Neuron Interface: Partial Tripolar, Single-Channel Thresholds and Psychophysical Tuning Curves: ...
Multi-channel electroencephalography of cortical evoked activity was measured repeatedly over time at: 1) acute (0.5 ± 0.7 weeks); 2) early chronic (1.1 ± 0.2 months); and 3) chronic (5.8 ± 3.4 months) cochlear implant stimulation. Results indicated consistent responses ...
Eighteen patients with a 22 channel cochlear implant were evaluated both pre and postoperatively with vestibular function tests; caloric test and body bala... T Himi,T Shintani,T Yamaguchi,... - 《Nippon Jibiinkoka Gakkai Kaiho》 被引量: 3发表: 1995年 The role of the promontory stimulation...
Amplitude modulation frequency discrimination (AMFD) measured in cochlear implants.No significant difference in AMFD with similarly loud single or multiple channels.Current levels must be reduced to accommodate multi-channel loudness summation.With summation-adjusted levels, AMFD better with multiple than sin...
Speech intelligibility was measured in 31 children who used the 3M/House single-channel implant (n = 12), the Nucleus 22-Channel Cochlear Implant System (n... MJ Osberger,M Maso,LK Sam - 《J Speech Hear Res》 被引量: 508发表: 1993年 Automatic Stage Scoring of Single-Channel Sleep EEG...