需要金币:*** 金币(10金币=人民币1元) SIEMENS西门子 SINAMICS G120X 变频器操作说明 EN.pdf 关闭预览 想预览更多内容,点击免费在线预览全文 免费在线预览全文 Operating instructions SINAMICS SINAMICS G120X Infrastructure converter for HVAC/water/wastewater Edition 06/2021 /drives Fundamental safety 1 instructi...
该功能模块中包含下列子功能: – 利用无功电流进行电网动态支持(可设置对称及不对称的电网支持) – 在出现电网故障时提供短路电流(穿越电网故障,Fault Ride Through),满足并网 标准 – 利用频移算法主动进行孤岛电网识别 – 扩展式电压检测及频率检测,用于电网故障后的自动重启 – 可自定义的控制点曲线(电压-时间...
SINAMICS Drive Software DC-DC Converters Motors Geared Motors Selection and engineering tools Further Components Digital Drivetrain Automation technology Energy Building Technologies Low-Voltage controls and distribution Market-specific solutions Services Software ... and everything else you need Configurator Ove...
SINAMICS S120 drive system SINAMICS S220 drive system SIMOTICS servomotors SIMOTICS servo geared motors SIMOTICS main motors SIMOTICS linear motors SIMOTICS torque motors Motion Control Encoder measuring systems MOTION-CONNECT connection systems Tools and configuration ...
SIDRIVE IQ Troubleshoot provides a list of possible root causes for a number of common faults and allows you to pinpoint the fault based on detailed video and text information, as well as inform your service technician, if necessary. With SIDRIVE IQ View you get a realistic impression of ...
Following is fault description from List Manual to help with troubleshooting. F07410 Drive: Current controller output limited Message value: - Drive object: SERVO Reaction: OFF2 (NONE, OFF1) Acknowledge: IMMEDIATELYCause: The condition "I_act = 0 and Uq_set_1 longer than 16 ms at its ...
NEW: SIMATIC S7 TIA Portal upgrade Course for Maintenance Personnel You as a maintenance technician ensure the availability of machines and systems during operation. We have developed this course for you, focusing on troubleshooting and fault elimination. And you can deepen your theoretical knowledg...
Drive: Function not supported Cause: The power unit does not support the selected function. Fault value (r0949, interpret decimal): 1: The function "Current controller dynamics higher" (p1810.11 = 1) is selected, however is not supported by the power unit (r0192.27 = 0). - firmware of ...
Drive parameterization with SINAMICS Startdrive Parameterization software for SIRIUS and SIMOCODE Power distribution in TIA Portal All details: Software and functions TIA Portal contains a wide range of functions and options for the Digital Enterprise, in order to resolve the challenges of Industrie 4.0....
The complete package for your automation solution optimizes your engineering processes With TIA Portal you not only integrate the basic software (STEP 7, WinCC, SINAMICS Startdrive, SIMOCODE ES and SIMOTION SCOUT TIA), but you also benefit from additional functionalities provided by new options...