说明与图示 打开 Starter 软件,在线 S120 设备,右键点击控制单元,在弹出的菜 单中选择"Load drive unit to PG". 设备名称前绿色连接符变绿色,表示上传成功 2. 点击画面左下角的"Alarms"标签按钮,可以查看当前存在的故障和 报警信息 如上图所示:其中 source 中显示报警组件名称,Message 中显示诊断 信息.可以双击...
With its separate power unit and Control Unit, the SINAMICS S120 drive system can be perfectly adapted to a wide variety of different drive tasks. The Control Unit is selected according to the number of drives to be controlled and the required performance level, while the power unit must be ...
the case of SOS, the speed setpoint is not influenced independently. After SLS has been selected, the higher-level control must bring the drive down below the selected speed limit within a parameterizable time. If the speed limit is exceeded, a customizable drive-integrated fault reaction ...
SIEMENS西门子 SINAMICS G120X 变频器操作说明 EN.pdf,Operating instructions SINAMICS SINAMICS G120X Infrastructure converter for HVAC/water/wastewater Edition 06/2021 /drives Fundamental safety 1 instructions Description 2 SINAMICS Mounting 3 Wiring 4 SINA
Hello everyone,In our factory we have carriers loaded that are going around the line and different mounting station and they are moved by a motor controlled by a Drive S120 CU320-2 PN. Sometimes out carrier goes to stop and we received the fault &quo
Dear all, I am facing problem in s120 drive with CU320. it was already commissioned running well but sometimes when 24V supply getting off after switch power CU showing F7800 fault that means power unit missing same one was already running. i was tri
SIEMENS西门子 SINAMICS G120XA 变频器操作说明 EN.pdf,Operating instructions SINAMICS SINAMICS G120XA Infrastructure converters for standard pumps/fans Edition 06/2021 /drives Fundamental safety 1 instructions Description 2 SINAMICS Mounting 3 Wiring 4 SIN
Drive technology Converters Safety extra low-voltage converter Low-voltage converters Standard performance frequency converters High performance frequency converters SINAMICS G220 built-in and wall-mounted units SINAMICS S220 built-in units SINAMICS S120 built-in units SINAMICS S120M distributed servo drive ...
The SINAMICS S120 drive system is suitable for operation in the second environment.Regarding interference immunity, SINAMICS S120 can be used in the first and second environments.Interference emission – complying with Category C2 first environment For use in the first environment, in addition to the...
My question: is the F07410 fault condition causing the output to the other motor to fail? IE Is the entire drive shutting down because of this? I would read through the manual, but I do not have a hard or soft copy, and have not been able to find the correct manual here. Thanks ...