Power Module ✓ = operation with Power Module permissible, = not per- missible CU240B-2 CU240E-2 PM230 IP20 and push-through ✓ ✓ PM230 IP55 ✓ PM240P-2 ✓ ✓ PM240-2 ✓ ✓ PM250 ✓ ✓ Installing the Control Unit - General Each Power Module has an appropriate ...
PM230 Power Modules, frame sizes FSA to FSC: In conjunction with the CU240E-2 Control Unit 1) Control of the STO safety function acc. to SIL 2 PM240P-2 Power Modules: Terminals for controlling STO and SS1 safety functions acc. to SIL 3 PM330 Power Modules: Terminals for controlling ...
The Forum is currently undergoing maintenance to improve your experience. During this time, the application will not be available. Thank you for your patience and understanding! This is our new SiePortal Platform. Take a tour to see what´s new....
Design and construction Internal arc classifi cation (option) Partition class PM (partition of metal) Designation of the internal arc Rated voltage 36 kV Loss of service continuity classifi cation IAC category for IAC class for panels or panel blocks – Wall-standing arrangement IAC A FL –...
PM240P-2 without integrated line filter, 22 kW and 132 kW PM330 without integrated line filter, 160 kW to 560 kW Line voltage 500 V to 690 V 3 AC PM240P-2 with integrated filter class A, 11 kW to 132 kW PM240P-2 without integrated line filter, 11 kW and 132 kW ...
需要金币:*** 金币(10金币=人民币1元) SIEMENS西门子 控制单元 CU230P-2操作说明 EN.pdf 关闭预览 想预览更多内容,点击免费在线预览全文 免费在线预览全文 Fundamental safety 1 ___ instructions 2 ___ Scope of delivery 3 ___ SINAMICS Installing 4 ___ SINAMICS G120P Commissioning CU230P-2 Control...
S7-1500 Welcome 1 Automation task 2 SIMATIC Hardware section 3 Software section S7-1500 4 Security 5 S7-1500 Motion Control Getting Started 6 SIMATIC Safety V17 10/2021 A5AD Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal...
PM240P-2 without integrated line filter, 22 kW and 132 kW PM330 without integrated line filter, 160 kW to 560 kW Line voltage 500 V to 690 V 3 AC PM240P-2 with integrated filter class A, 11 kW to 132 kW PM240P-2 without integrated line filter, 11 kW and 132 kW ...
An appropriate connection diagram for the standard wiring can be found in the documentation of the IOP‑2 operator panel. Commissioning of more demanding applications using plain text scripts through solution-based dialog prompting in the STARTER commissioning tool ...
PM240P-2 with integrated filter class A, 22 kW to 132 kW PM240P-2 without integrated line filter, 22 kW and 132 kW PM330 without integrated line filter, 160 kW to 560 kW Line voltage 500 V to 690 V 3 AC PM240P-2 with integrated filter class A, 11 kW to 132 kW ...