这里提一嘴,这个期刊一提交就是under review,没有中间环节。 2023.10.02 reject(revise and resubmit)三个审稿人(就简称A、B、C吧),均给的拒稿重投。当时看到这个决定,想着八成是凉了,但后来一查,好像这个期刊除了小修和接收,就是拒稿重投,突然又燃气了信心。 然后耐下性子,认真看了三个审稿人的评论,发现...
Opto-electronic humidity sensor: A review S. Sikarwar, B.C. Yadav, in Sensors and Actuators A: Physical, 2015 1 Introduction Humidity sensors are transducers that convert the amount of water (H2O) vapour into a measurable parameter. Humidity is one of the most frequently measured quantities in...
Karabulut and Bilgin [169] investigated the friction drilling behavior of AA 7075T6 aluminum and AZ31B magnesium alloy materials dry and under minimal lubrication. Zhu et al. [170] evaluated the tool temperature divisions in drilling of AA 2024-T351. The transfer of the data obtained from the...
2A, B). After the sensor signal, measured as the wavelength shift (WS) of the pixel corresponding to the maximal signal of the cell, reached a stable level (see Fig. 2C), the microplate was removed from the instrument and the morphology of the cells was examined with optical microscopy....
b Schematic illustration of the sensor’s working principle under applied pressure. c Iontronic membrane model with the fiber-like PVA distribution. d–e SEM of the PVA-KOH ionic film and its corresponding locally enlarged image (scale bar: 20 μm and 2 μm, respectively). f Tensile ...
Anil B. Patil, Umesh. J. Tupe, Vikas V. Deshmane, and Arun V. PatilSensor Lett. 18, 881–888 (2020)[Abstract] [Full Text - PDF] [Purchase Article] Design of a Sensor System Using Fiber Bragg Grating for Liquid Level and Liquid Density Measurement Kalyan Biswas Sensor Lett. 18, ...
Power functions: S = A + B.xk where x is the measurand, S is the electrical signal produced by the sensor, A and B are parameters, and k is the power factor. A polynomial function can be used when none of the functions previously described can be applied to describe the sensor tran...
Acknowledgements This work was supported by National Natural Science Foundation of China under Grants (U1805261 and 22161142024) and A*STAR SERC AME Programmatic Fund (A18A7b0058). Funding Open access funding provided by Shanghai Jiao Tong University. ...
input-referred system resolution value is obtained foran=4.03ng/Hz. Packaging of the resonator under vacuum will improve the quality factor, by reducing the damping by the (squeezed) air around the moving proof mass, in turn reducing the thermal noise contribution by a lower damping coefficientb...
Ethylene detection methods in post-harvest technology: A review F.Caprioli,L.Quercia, inSensors and Actuators B: Chemical, 2014 2.4Amperometric sensors Amperometric gas sensors are inexpensive and accurate devices based on the measurement of the current associated to theredox reactionof a certain analy...