Stenting of a stenosed Sano shunt in a neonate with hypoplastic left heart syndrome. Pediatr Cardiol. 2005; 26:877-8.Eicken A, Sebening W, Genz T, Schreiber C, Hess J. Stenting of a stenosed Sano shunt in a neonate with hypoplastic left heart syndrome. Pediatr Cardiol. 2005;26:877-8....
The right ventricle-pulmonary artery (RV-PA) shunt to reestablish pulmonary blood supply in stage I palliation for hypoplastic left heart syndrome (HLHS) was first introduced by Norwood et al in 1981.1 The shunt materials they used were relatively large for neonates: 8-mm nonvalved polytetra...
The contemporary surgical management of this anomaly includes the Norwood procedure and provision of pulmonary blood flow by either a modified Blalock-Taussig shunt (MBTS) or a right ventricle-to-pulmonary artery (RV-PA) conduit, commonly referred to as the Sano shunt. We report on an unusual ...
二.室-肺分流术/Sano shunt 三.各种分流术的临床应用 3-1.根治术前的姑息性手术 3-2.Fontan循环的组成部分 3-3.最终的姑息性手术 3-4.不同的分流术的比较 上篇,我们回顾了各种各样的体-肺循环分流术和他们的历史,我们知道,这些分流术依靠的都是主动脉压力远比肺动脉高的特点,在一次一次的改进中,Watersto...
Further studies will be required to determine conclusively whether the RV-PA shunt confers protective effects in the AA-MS subgroup compared with the mBTS.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery...
SanoAngioplastyThrombusWe describe a case of thrombus formation within a right ventricle-to-pulmonary artery conduit (Sano shunt) in a patient with hypoplastic left heart syndrome with resulting acute cyanosis and hypotension requiring emergency balloon angioplasty....
Stenting of a Stenosed Sano Shunt After Palliation in Hypoplastic Left Heart Syndromedoi:10.1016/j.athoracsur.2005.12.023AndreasEickenandChristianSchreiberSDOSThe Annals of Thoracic SurgeryEicken A, Schreiber C (2006) Stenting of a stenosed Sano shunt after palliation in hypoplastic left heart ...
Femoral vein homograft as Sano shunt results in improved pulmonary artery growth after Norwood operationdoi:10.1017/s1047951117001688Mario Briceno-MedinaT. K.Susheel KumarShyam SathanandamUmar BostonMichael PerezJerry AllenDavid ZurakowskiMichel N. Ilbawi...
Shunt burden was assessed by averaging WSS, over its luminal area and the cardiac cycle. For the central shunts, these WSSs were 73.0 and 67.2 Pa; whereas, for the Sano shunts, 34.9 and 19.6 Pa. For modified Blalock-Taussig shunts (4 and 3.5 mm), the averaged WSSs were ...
282: PULMONARY EMBOLISM IN A NEONATE FOLLOWING MODIFIED NORWOOD PROCEDURE WITH SANO SHUNTdoi:10.1097/01.ccm.0000551036.57510.48Sarah SchlueterAwni Al-SubuPetros AnagnostopoulosMichael WilhelmCritical Care Medicine