Control Unit is booted 111 3.1.2 LEDs after the Control Unit CU320 has booted 112 3.1.3 LEDs after the Control Unit CU310 has booted 114 3.1.4 Active Line Module 115 3.1.5 Basic Line Module 116 3.1.6 5 kW and 10 kW Smart Line Modules 117 3.1.7 Smart Line Modules ≥ 16 kW 118...
1.4Linecontactorcontrol...1-38 1.5Pre-chargingandbypasscontactorchassis...1-40 2ExtendedSetpointChannel...2-41 2.1Extendedsetpointchannelservo...2-42 2.1.1DynamicServoControl(DSC)...2-42 2.1.2Activatingthe“extendedsetpointchannel”functionmoduleinservomode2-43 2.2Extended...
only available in Interface Mode p2038 = 0 Parameter r0899.0 r0899.1 r0899.2 r0899.6 r0899.11 Function diagrams (see SINAMICS S120/S150 List Manual) ● 2610 Sequence control - sequencer ● 2634 Missing enable signals, line contactor control ● 8732 Basic Infeed - sequencer ● 8832 Smart Infeed...
(搜索手册或信息) /motioncontrol/docu 如果您对技术文档有疑问(例如:建议或修改),请发送一份电子邮件到下列地址: docu.motioncontrol@ 我的文档管理器 如何在西门子文档内容的基础上创建自定义文档,与自己的机床文档相匹配,请访问以下 链接: /mdm 培训 通过以下链接可获取有关 SITRAIN 的信息 - 西门子为自动化...
Disable Line filter 3 DI, Reset 4 M c 0 3 0 0 0 _ N E _ 1 1 2 Line reactor 1 U 2 V W D _ G 1 X 1 1 1 U V W 1) Leading NC contact t 10 ms 2) DI/DO controlled by the Control Unit 3) No additional consumer permitted downstream of the line contactor 4) The curre...
Communication system for connecting the various components of a SINAMICS drive system, such as the → Control Unit, the → Line Modules, the → Motor Modules, the → Motors and speed/position encoders. The DRIVE-CLiQ hardware is based on the Industrial Ethernet standard and uses twisted-pair ...
is indicated via two multi-color LEDs.The scope of supply of the Active Line Modules includes:•Frame sizes FX and GX: -0.60 m (1.97ft) DRIVE-CLiQ cable for connection to the CU320 Control Unit or SINUMERIK solution line NCU ■ Technical specifications General technical specifications ...
This module contains the line-side components required for an → Active Line Module, e.g. the pre-charging circuit (pre-charging resistors and bypass contactor). Active Line Module A regulated, self-commutated infeed/regenerative feedback unit (with IGBTs in infeed/feedback direction) which su...
下表中举例说明了使用调试工具 STARTER 进行调试的步骤。 列表: 使用调试工具 STARTER 进行调试的步骤(示例) 注意 通过另一个控制单元控制会损坏电源模块 如果电源模块是由控制单元控制,而不是由电机模块控制,则电源模块的就绪信号 r0863.0 须和驱动的参数 p0864 “电源就绪”通过一个数字量输入/输出互联在一起。如...
可以在 “Function > Line contactor control”窗口中检查互联连接。 7. 备份设备中的参数 1.调用菜单“Project” > “Connect to selected target device ”(在线模式)。 2.调用菜单“Target system > Load > load CPU/drive unit to target device...”。 在驱动设备上点击鼠标左键(SINAMICS S120)。