在4线RTD 配置中,两条线将RTD连接到监控设备(图1中的RL2和RL3),另外两条线(RL1和RL4)传输用于测量的电流。将激励电流线与测量线分开可消除2线和3线配置中的误差源。此配置可产生最准确的测量结果,但实施起来最复杂、最耗时且成本最高。 改善2线和3线测量的桥梁 Bridges to improved 2- and 3-wire measur...
4线RTD,-50 ~ 250°C, 长 305mm,直径6.35mm PR-10L-3-100-3/16-2-134 ¥710.00 货期: 2 周 RTD Probe with Insulated Wire and Shrink-Tube Support †所有金额以RMB显示 注:* 请以毫米为单位填上探头直径:"-M30"代表3 mm, "-M45"代表4.5 mm, 或"-M60"代表6 mm。如欲订购带应力消除收缩...
To order style 3 (4-wire), replace the “-2-” with “-3-” in the model number. For leads over 36", change the “36” in the model number to length desired and add $2.25/ft (Styles 2 & 3) or $1.40/ft (Style 1). Other RTD elements are also available with lead wire ...
RTD probes and wires come in a variety of configurations, including 2-wire, 3-wire, and 4-wire models. There are significant differences between these types, and these differences must be taken into consideration when selection the appropriate device for an application. Factors to Consider When...
depending on the instrument circuitry. A 2 wire RTD can be used with either a 3-4 wire instrument by jumping the appropriate terminals, although this defeats the purpose and reintroduces the uncompensated resistance of the leads. To get the optimum performance, it is generally best to specify ...
Rtd measurement unit including detection mechanism for automatic selection of 3-wire or 4-wire rtd measurement mode.An RTD measurement device including a mechanism for automatic selection of a 3-wire or 4-wire configuration mode of operation. The RTD measurement device may i...
显示全部generic,类的,种类的,属。 wire,电线,电缆。 rtd,热电阻信号。 总之就是两线制/三线制...
RTDs: 100Ω platinum, 0.00385 Ω/Ω/°C; 2-, 3- and 4-wire single element configurations, Class 'B' tolerance to DIN 43760:1980 and IEC 751:1995 Silver plated, stranded copper conductors, 24 AWG, Teflon® insulated with extruded Teflon jacket overall or 24 or 26 AWG, Teflon insulated...
An RTD measurement device including a mechanism for automatic selection of a 3-wire or 4-wire configuration mode of operation. The RTD measurement device may include detection circuitry to detect whet
Bridges to improved 2- and 3-wire measurements 在使用 2 线和 3 线 RTD 设备时,惠斯通电桥配置可用于提高精度。要检测 2 线配置 RTD 中电阻的微小变化,可以使用惠斯登电桥形式的温度变送器(图 3A)。该电路将 RTD 值与三个已知的高精度电阻进行比较。在该电路中,当流经测量设备的电流 (Vout ) 为零时,...