maximum cable length 4000 feet maximum data rate 10 Mbps max. driver output voltage -0.25V to +6V Max. driver current in high impedance state (power off) +/-100 µA receiver input voltage range -10V to +10V Receiver input sensitivity +/-200mV Driver load impedance 100 Ohms Rece...
RS-422 (EIA RS-422-A Standard) is the serial connection used on legacy Apple computers. It provides a mechanism for transmitting data up to 10 Mbits/s. RS-422 sends each signal using two wires to increase the maximum baud rate and cable length. RS-422 is also specified for multi-drop ...
Advantech B+B SmartWorx s.r.o. RS485 RS422 扩展端口用户手 Expansion Port RS485/RS422 USER MANUAL
Also, up to nine additional receivers can be placed along the cable from points A and B to points A and B, respectively. No restriction on maximum cable length is imposed by the RS-422 standard. Taking this into account, systems of up to 1 km are not uncommon, with signaling rates no...
Cable Length:5.0m Cable Details:9 core, 5mm UL2464 28 AWG Packages:N/A Channels:1 I/O Voltage:RS422 USB Class:FTDI Drivers Virtual Com Port:Yes Max Power Output:- FTDI Internal IC:FT232R Operating Temperature:-40°C to +85°C ...
Cable Length:1.8m Cable Details:9 core, 5mm UL2464 28 AWG Packages:N/A Channels:1 I/O Voltage:RS422 USB Class:FTDI Drivers Virtual Com Port:Yes Max Power Output:- FTDI Internal IC:FT232R Operating Temperature:-40°C to +85°C ...
RS-232/422 Low Cap, #24-4pr, FPO, O/A Foil+Braid, PVC Jkt, CM, 100Ω Product Description Computer EIA RS-232/422 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) + tinned copper braid shield (65%...
The decision whether or not to use termination should be based on the cable length and data rate used by the system. A good rule of thumb is if the propagation delay of the data line is much less than one bit width, termination is not needed. This rule makes the assumption that ...
Cable length max. 500 m twisted pair Common-mode voltage UCM max. -7…+12 V to ground Data buffer 128 bytes receive buffer, 16 bytes transmit buffer Power supply connection feed: 1 x M8 male socket, 4-pin; downstream connection: 1 x M8 female socket, 4-pin Current consumption from US...
Interfacesindividually selectable from RS232, RS485, RS422 Data transfer rates300…115,200 baud; 9600 baud (8 bit, no parity, 1 stop bit) is preset CommunicationTxD and RxD, full duplex Bit distortion< 3% Cable lengthRS232: max. 15 m; RS422/RS485: approx. 1000 m ...