Czapla-Myers, J.; Anderson, N.; Thome, K.; Bigger, S. The absolute radiometric calibration of the Landsat 8 Operational Land Imager using the reflectance-based approach and the Radiometric Calibration Test Site (RadCaTS). Proc. SPIE 2014, 9218, doi:10.1117/12.2063321....
Landsat⁃8 Thermal Infrared Sensor ( TIRS) vicarious radiometric calibra⁃ tion. Remote Sensing, 2014, 6: 11607-11626Barsi J A, Schott J R, Hook S J, Raqueno N G, Markham B L, Radocinski R G. Landsat-8 thermal infrared sensor (TIRS) vicarious radiometric calibration. Remote Sensing...
M. (1987), Radiometric comparison of the LANDSAT-5 TM and MSS sensors, Int. J. Remote Sens. 8(4):579-591.A. Royer, L. Charbonneau, R. Brochu, J. Murphy, and P. Teillet, Radiometric comparison of the Landsat-5 TM and MSS sensors, International Journal of Remote Sensing 8 (4):...
The spatial resolution of the SRTM data is 3 arc seconds (approximately 90 m). The SRTM digital elevation data of the study area was hill-shaded using 45° light angle at azimuths of 112.5° and 337.5° (Figs. 4, 5) to highlight east-northeast and north-northeast structural trends, ...
Performance of Landsat ETM+, OLI and OLI-2 Imagery in ICESat-2-Aided Coastal Bathymetry: The Effect of Radiometric Resolution Performance of Landsat ETM+, OLI and OLI-2 Imagery in ICESat-2-Aided Coastal Bathymetry: The Effect of Radiometric Resolution... G Zhang,S Xing,Q Xu,... - 《...
A radiometric math model (RMM) has been developed for use as an analytical tool to establish design requirements and to model performance of the moderate resolution imaging spectroradiometer (MODIS) instrument design. The MODIS instrument is scheduled for flight on the first earth observing system (...
Excellent ground reference information and fine-resolution DEM allowed precise assessment of the applicability of the methods under investigation. The results of the study presented here demonstrate the weakness of the classical cosine correction method for radiometric correction in rugged terrain. The ...
An In-Flight Radiometric Calibration Method Considering Adjacency Effects for High-Resolution Optical Sensors Over Artificial Targets When using a field calibration site to perform in-orbit radiometric calibration of a space-borne remote sensor, the measured signal by the sensor may conta... L Ma,N...
Launched in April 1999, the Landsat-7 ETM+ instrument is in its fourth year of operation. The quality of the acquired calibrated imagery continues to be high, especially with respect to its three most important radiometric performance parameters: reflective band instrument stability to better than ...
Landsat-5 TM reflective-band absolute radiometric calibration The Landsat-5 Thematic Mapper (TM) sensor provides the longest running continuous dataset of moderate spatial resolution remote sensing imagery, dating bac... G Chander,DL Helder,BL Markham,... - 《IEEE Transactions on Geoscience & Remote...