Developing a collaborative control strategy of a combined radiant floor cooling and ventilation system: A PMV-based model 2022, Journal of Building Engineering Citation Excerpt : As shown in Fig. 5, the schematic diagram of the integrated RFC and DV system is presented. The following boundary cond...
Fig. 6. The cold source type of the radiant floor system. (a) Schematic diagram of the direct-ground cooling system with RFCS [11], and (b) Schematic drawing of direct-ground cold source system in summer [76]. 2.2. Combination with air system The air system is crucial for the radiant...
Radiant heated floorsare proving to be one of the most popular options among new homeowners today. With virtually no heat loss, precise control, and luxurious warmth, radiant heat looks to be the future of home heating. ProLine also carries a diverse selection of premium floor heating systems,...
The schematic of radiant heating system and coordinate system is shown in Figure 1. The radiant floor is assumed as the constant temperature Tfl; the outside wall is cooled at the constant heat flux qow; other walls are adiabatic. The air velocity at the inlet is uin, and the inflow ...
A radiant heating system includes an air-to-fluid heat exchanger, a radiant heating loop and a pump and conduits to circulate heating fluid between the air-to-fluid heat exchanger and the radiant flui
FIG. 1 is a side, partially cross-sectioned, partially-schematic view of one embodiment of the radiant convection oven of this invention; FIG. 2 is a partial end elevation of the radiant convection shown in FIG. 1. DETAILED DESCRIPTION OF THE PREFERRED EMBODIMENT As set forth above, the ra...
(B) Schematic diagram of the pure radiant cooling device. We used a thermoelectric cooling (TEC) module as the cooling source, with a heat sink on the hot side and an aluminum panel with high emissive coating on the cold side. 2-layer polyethylene (PE) films were integrated on the alumin...
1 (b) presents the schematic of the proposed system consisting of a water pump circulating the water in the PCRC and a portable radiant chiller to cool down the water. It is noteworthy that each radiant cubicle is well insulated on all sides that are unexposed to the occupant body in ...
The traditional on–off and PID control methods could be implemented through the components in TRNSYS simulation software. Figure 1. Schematic diagram of radiant ceiling cooling room model. 3.1.1. Simulation Environment Compared to more developed HVAC systems, environmental control simulations for ...
(a) Schematic of the LOBSTER (the two test-rooms and the anteroom) and (b) view into one of the two offices at the LOBSTER which demonstrates the positions of the participants in respect to the front walls (artificial windows) and the position of sensors. (a) (b) Figure 4 presents ...