A. The desired deposit thickness must be specified after the process standard number using a Αcode” designation. For example, the designation “PS-8955 Ni Code 30” means a zinc-nickel alloy deposit with a thickness of 8 micrometers or 0.00030 inch.B. Parts with a hardness of ...
“PS-8955 Ni Code 30” means a zinc-nickel alloy deposit with a thickness of 8 micrometers or 0.00030 inch. B. Parts with a hardness of Rockwell HRC 32 or greater require a mandatory bake for hydrogen embrittlement relief according to Process Standard PS-9500<S> (Hydrogen ...