Ionic mechanisms of adenosine actions in pacemaker cells from rabbit heart. 1. Whole-cell and patch clamp techniques have been applied to cells isolated from the rabbit sino-atrial (S-A) node to study the ionic mechanism(s) of aden... L Belardinelli,WR Giles,A West - 《J Physiol》 被...
GW25-e3359 One case of heart pacemaker implantation 10 years after primary heart transplantationCardiac sympathetic denervation (CSD) has been shown to reduce the burden of implantable cardioverter-defibrillator (ICD) shocks in small series of patients with structural heart disease (SHD) and recurrent...
Central venous cannulation by the subclavian approach is a commonly performed procedure with an overall complication rate of up to 11%. In the English lite... F, Follis,KB Miller,RF Paone,... - 《Tex Heart Inst J》 被引量: 6发表: 1992年 Removal of Infected Pacemaker Leads with Deep ...
Remote monitoring of implantable pacemaker cardioverter defibrillator and cardiac resynchronizer 热度: Sudden Cardiac Death Epidemiology Mechanisms and Therapy 热度: Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure 热度: 相关推荐 ChinMedJ201 123(7):848-851 Originalarticle ...
2 TAP Dilated RV, fatigue Pulmonary valve replacement with homograft, pacemaker 20 3 TAP VT AICD 19 4 Primary closure of transverse infundibulotomy RVOTO, DCRV Resection of muscle bundles, patch closure 18 5 Non-TAP and aortopulmonary window patch repair RVOTO Resection of supravalvular membran...
et al. Sarcoplasmic reticulum Ca2+ cycling protein phosphorylation in a physiologic Ca2+ milieu unleashes a high-power, rhythmic Ca2+ clock in ventricular myocytes: Relevance to arrhythmias and bio-pacemaker design. Journal of Molecular & Cellular Cardiology 66, 106–115 (2014). 50. Junyi, M. ...
Most implantable pacemaker batteries are lithium-based, draw only 10–20 microamperes (µA) and last 5–10 years. Many hearing aid batteries are also primary with a capacity from 70–600mAh, good for 5–14 days before a replacement is needed. The rechargeable version offers less capacity ...
AUC was slightly higher (by up to 0.02) in individuals without a pacemaker (n = 408). Exclusion of those with a low pulse rate (< 48 beats/minute; n = 19) did not alter discrimination performance compared to in the total sample. When analysis was restricted to those with ...
One patient had tamponade most likely due to a temporary pacemaker lead. Before transport to Maastricht University Medical Centre for emergency cardiac surgery, this patient died as a result of rupture of the right ventricle. This was considered a procedure-related death. Procedural complications of ...
We also excluded those who were acutely hospitalized with a primary/secondary diagnosis of a concomitant condition potentially necessitating a pacemaker. A full list of codes for inclusion and exclusion criteria is available in Online Supplement 1 Table 1. Clinical settings of ICD placement All ...