In this study, the seismic and static performance of post-installed anchors (bars) using chemical bonding (epoxy adhesive mortar) in cracked and uncracked reinforced concrete was analyzed using Hilti International software (Hilti PROFIS Anchor soft.). For this purpose, 52 concrete specimens with ...
Basics of post-installed rebar connectionsReinforcement anchorages or splices that are fixed into already cured concrete by Hilti HIT injection adhesives in drilled holes are called "Post-installed rebar connections" as opposed to normal, so called "cast-in" reinforcement. Many connections of rebars ...