Table 1. Comparison of characteristics of PET, PEN, PES, PI substrate with a thickness of 0.1 mm [7] Empty CellPETPENPESPI Tg (°C) 80 150 223 >300 Water absorption ratio (%) 0.5 0.4 1.4 2–3 Total light transmittance (%) 90.4 87.0 89.0 30–60 Coefficient of thermal expansion...
Poly(ethylene oxide) (gold nanoparticles) (1.5%) solutions, concentrations of ethidium bromide were 5 and 0.5 μg/mL in the separation channel and the anodic reservoir, respectively, prepared in 100 mM glycine-citrate buffer, pH 9.2. The separations were conducted at 2400 V.Reprinted from ...
Part of our design included co-delivering the polymers with a CPE. 32 mM sodium octyl sulfate (SOS) was injected with 3 µg (18 µM) of free TTX in 0.5 mL of PBS at the sciatic nerve; that concentration of SOS had been shown to prolong nerve block from TTX12,13. SO...
关键词: biological rationale molecular weight (MW) drug molecules pharmacokinetics (PK polymer‐drug conjugates 被引量: 21 摘要: A conjugate that includes a drug covalently linked to a polymer. Upon administration, the conjugate is digested by an enzyme that is present at the site of ...
The inter-electrode distance between Ag/AgCl electrodes is fixed at 33 mm corresponding to a 64 electrodes configuration on the head63. On the other hand, TTEs are placed at 20 mm center-to-center distance in order to double the density of electrodes with respect to the Ag/AgCl case...
All TPU samples were filtered using 0.22 µm polytetrafluoroethylene (PTFE) syringe filters and introduced to a GPC equipped with Phenogel 5 µm 104 Å 300 × 7.80 mm GPC/SEC Column (Phenomenex, Torrance, CA, USA). Ultraviolet and refractive index detectors (Wyatt ...
(1 mM) was then added into The aqueous mixture of Cu(NO3)2 the water gently and slowly (0.5 ml (5 mM) min À 1) and NaBr by using a syringe pump. Formation of the film can be observed with naked eyes at the 0.1 0.0 –0.1 –0.2 Binding energy (eV) dichloromethane–water ...
The blend samples were placed between two gold electrodes (Goodfellow, >99.95%) of 10 mm diameter and pretreated at 60 °C in a Buchi TO51 oven. The Nyquist plots were measured using the Autolab PGSTAT-12 (Eco Chemie) equipment in the temperature range from 25 to 80 °C. The ionic ...
100 8 7 8 9 – 28 13 12 Elongation at Break in % (5 mm/min) ASTM D638 −40 – 9 12 11 – 94 50 30 23 19 11 14 13 25 >150 80 75 70 – – – – – >100 >100 >100 100 >100 >100 – – – >100 >100 >100 Tensile Modulus in MP...
The device structure is shown in the inset of panel (a), where FET channel length and width are 150 mm and 1 mm, respectively. accumulation) state, in an operating FET. Unlike other CMS tech- niques, where the charge in the channel is modulated around a specific bias point in the ON...