Every time you clean your probe, calibrate it using Bluelab Calibration Solutions. In addition, boost your probe’s lifespan by ensuring that its tip stays wet at all times. Use the included storage cap whenever you’re not using your probe and regularly top up the amount of KCl inside ...
Get calibration services and certificates for METTLER TOLEDO pH sensors. Achieve and maintain compliance through consistent procedures and adherence to industry regulations and standards. Gain more confidence in your measurements with calibration and cer
pH传感器护套为过程连接硬件,可用来将传感器安装在过程中,确保最佳测量结果和传感器保护。 梅特勒托利多pH传感器护套采用多种设计,可在常见过程环境中实现强度、安全性、洁净度与优化性能。 为了最适合您的应用需求,pH和ORP传感器护套种类繁多,从简单的浸入式配件到自动化的伸缩式系统不等。 需要更多信息需要报价 ...
Keep your pH probe calibrated! Neptune Systems single-use pH calibration packets make calibrating your pH probe simple and fast. Just tear open the top, and a stick your probe into the solution when performing the calibration procedure. Over the course
Measuring range PH: 0.00-14.00 PH; T: 0.1°C-80°C Resolution PH: 0.01PH; T : 0.1°C Battery 3 *1.5 V( AG-13 button cell) Operation temperature 0---80°C Calibration Automatic two point calibration Auto shut off function 4 minutes Size/Weight 183mm*37mm*37mm/80g Product S...
There are several things you should check if you’re experiencing pH calibration problems. 1. Check the Age of the Probe Probes, or electrodes, for your pH meter generally last 12-18 months. This holds true whether the probe is being used or not. The "lot code" will determine the age...
pH calibration pointsUp to 6Up to 5Up to 5 mV, RmV/ORP modesYesYesYes Temperature range-5 to 105°C 23 to 221°F-30 to 130°C -22 to 266°F-5 to 105°C 23 to 221°F Number of channels4, customizable with modules11 Stirrer probe inputs21— ...
pH calibration pointsUp to 6Up to 5Up to 5 mV, RmV/ORP modesYesYesYes Temperature range-5 to 105°C 23 to 221°F-30 to 130°C -22 to 266°F-5 to 105°C 23 to 221°F Number of channels4, customizable with modules11 Stirrer probe inputs21— ...
The pH-probe has a low standard deviation (±4 mV or 0.07 pH units). The response time is short (5 s). To characterize its function the soil pH-probe was used to analyse pond and arable soil samples. The results were compared with those obtained with a conventional combined ...
Calibration of pH Meters Use the following four steps in the calibration of pH meters. Step 1: Clean the Electrodes If working with laboratory equipment and chemicals, it is important to wear proper safety equipment, such as gloves and safety glasses. After turning on the power to the pH met...