SimPET-L and SimPET-XL have recently been introduced with increased transaxial fields of view (FOV) compared with their predecessors (SimPET and SimPET-X), enabling whole-body positron emission tomography (PET) imaging of rats. We conducted performance evaluations of SimPET-L and SimPET-XL ...
Negative predictive value PBS: Phosphate buffered saline PET-PCR: PCR based on photo-induced electron transfer fluorogenic primers PPV: Positive predictive value qPCR: Quantitative PCR ROC: Receiver operating curve RPM: Revolutions per minute WHO: World Health Organization 6FAM: 6-Carboxyfl...
which are the larger blood pools but inside mouse or rat, the sizes are very small [102]. To image these blood pools with a high efficiency during the dynamic studies, the PET scanners need to have high sensitivity which can be derived from an axial field-of-view that is longer than th...
as measured for a point source at the center of the scanner, and better than the 1 mm resolution. To obtain high spatial resolution across the FOV, all these four scanners are based on detectors
Tau PET positivity comparison with visual rating, using automate quantitative methoddoi:10.1002/alz.082890Choe, Yeong SimHa, SeunggyunKim, Regina EYLim, Hyun KookKim, Hye WeonAlzheimer's & Dementia: The Journal of the Alzheimer's Association...
Carole Poitry-YamateCIBM Center for Biomedical Imaging, Switzerland;Dunja SimicicCIBM Center for Biomedical Imaging, Switzerland;Mario LeporeCIBM Center for Biomedical Imaging, Switzerland;Valérie A. McLinSwiss Pediatric Liver Center, Department of Pediatrics, Gynecology and Obstetrics, University Hospitals ...
SSTR imaging is useful in deciding site of biopsy, assessing response to therapy and for prognostication.doi:10.4103/ijnm.ijnm_134_22Jaleel, JasimPatel, Chetan D.Chandra, Khangembam BangkimRamakrishnan, SivasubramanianSeth, SandeepIndian Journal of Nuclear Medicine...
Besides the immense increase in sensitivity and the diagnostic value that is associated with the first generation of TB PET/CT systems, there remain some challenges to be faced. However, if overcoming issues regarding patient comfort and space requirements, there are even more potential fields of ...
The diagnostic value of PET/CT scanning in patients with cervical cancer: A prospective study. Gynecol. Oncol. 2007, 106, 29–34. [Google Scholar] [CrossRef] Zhu, Y.; Shen, B.; Pei, X.; Liu, H.; Li, G. CT, MRI, and PET imaging features in cervical cancer staging and lymph ...
(21 subsets, 2 iterations). The image matrix was 200 × 200 with a voxel size of 4.07 × 4.07 × 3.0 mm3. The volume of interest (VOI) for the breast lesion was delineated on PET images using a threshold of 2.5 of the maximum standardized uptake value (SUVmax) in MIM version 6.4 ...