(PEG) catheter for enteral feeding, which comprises a clamp-type radial retention means that holds the catheter to prevent it from migrating into the patient's stomach cavity, said clamp being secured in its position by a locking button for coupling laterally to the catheter and by a perimeter...
PP237-SUN: Replacement of Percutaneous Endscopic Gastrostomy (PEG) Catheter by using a Portable Multiscope and Wireless Internet Techniquedoi:10.1016/S0261-5614(14)50278-6C.MiharaH.SatoSDOSClinical Nutrition
BACKGROUND/PURPOSE: Percutaneous endoscopic gastrostomy (PEG) is a simplified catheter placement procedure for alimentation. Although the endoscopic approach to gastrostomy tube placement is a safe and well-tolerated procedure in most patients, the PEG procedure is difficult in elderly patients disabled ...
Medical Intracranial Balloon Dilatation Catheter US$100.00-150.00 / Piece Advanced Intracranial Balloon Dilatation Catheter for Neuro Procedures US$100.00-150.00 / Piece Medical Intracranial Balloon Dilatation Catheter US$10.00-20.00 / Piece Disposable ...
These findings imply that the catheters coated with PEG/PVA have a potential to control the drug release rates to a desired value for urinary catheterization. 展开 关键词: hospital infection coated catheter in vitro release antimicrobial activity atomic force microscopy DOI: 10.1007/s13726-012-...
在夹钳实验钱大约1星期,在三氟溴氯乙烷麻醉时,将聚乙烯导管(Tygoncatheter)插入到颈静脉中(进行输注)和颈动脉中(用于血液取样),用手术从腹中取出并固定在颈部的后边。在外科手术之后为大鼠vet.给药链霉素(Streptocilin)(Boehringer Ingelheim;0.15ml/rat,i.m.),并在恢复期中置于动物饲养单元(25℃)中。为了达到...
Type: Catheter Material: Medical Grade Silicone Contact Supplier Chat Still deciding? Get samples of US$ 6/Piece Request Sample Hangzhou Fushan Medical Appliances Co., Ltd. Manufacturer/Factory & Trading Company Diamond Member Since 2022...
电磁波在运动导电介质中的传导效应 17. Research on Active-Catheter Navigation in Minimally Invasive Vascular Surgery 血管微创介入手术导管导航技术研究 18. Translation Control Regulated by TOR Signaling Pathway TOR信号转导通路介导的翻译控制©2011 dictall.com...
BACKGROUND Adhesions resulting from previous abdominal surgery can cause migration, kinking and obstruction of catheters in patients initiating continuous ... Crabtree,H John - 《Nature Clinical Practice Nephrology》 被引量: 16发表: 2008年 Previous abdominal surgery is not necessarily a contraindication...
Needle-catheter assembly Surgical blade, No. 11, attached to a scalpel Gauze Lubricant Scissors Swab sticks containing povidone-iodine solution Percutaneous endoscopic gastrostomy (PEG) tube. Image courtesy of Wikimedia Commons. View Media Gallery Next: Patient Preparation What to Read Nex...