1.The paper analyzes the features of three RLCparallel resonant circuits of different structure,including its admittance,resonant frequency,quality factor,and their relationship.文章分析了三种不同结构的RLC并联谐振电路的输入复导纳、谐振频率和品质因数Q,指出了它们之间的联系,为选择RLC并联谐振电路提供一定的依据。
4) parallel resonant circuit 并联谐振电路 1. The paper analyzes the features of three RLCparallel resonant circuits of different structure,including its admittance,resonant frequency,quality factor,and their relationship. 文章分析了三种不同结构的RLC并联谐振电路的输入复导纳、谐振频率和品质因数Q,指出了它们...
1) parallel-tuned circuit 并联调谐电路2) parallel resonant circuit 并联谐振电路 1. The paper analyzes the features of three RLC parallel resonant circuits of different structure,including its admittance,resonant frequency,quality factor,and their relationship. 文章分析了三种不同结构的RLC并联谐振电路...
1.2Literature review Control strategies for parallel inverters in the microgrid (MG) can be classified as master/slave (MS), current sharing, droop control, virtual synchronous machine (VSM)-based and virtual oscillator control (VOC) methods. The MS and current sharing methods both have the disad...
So, the quality factor of parallel resonant circuit isQ0−factor=Rω0L=RLC−−−√L=RCL−−√Q0−factor=Rω0L=RLCL=RCLNumerical Example The applied voltage in a parallel RLC circuit is given byu=100sin(314t+π4)Vu=100sin(314t+π4)VIf the values of R, L and C be...
This causes resonance of a larger amplitude and a larger quality factor. In the next step, a short circuit between two discs, 9 and 10, was introduced into the winding, and the measurement was performed. This location was chosen to be approximately in the middle of the column and without ...
When the fully controlled device is switched off, the circuit in which 𝑖1i1 is located at this time is an RLC series circuit, and the relationship between 𝑖1i1 and the input voltage can be obtained as follows: 𝑢𝑖=𝑖𝑅+𝐿𝑑𝑖𝑑𝑡+1𝑐∫𝑖𝑑𝑡ui=iR+Ldidt+...
Transient stability studies are made to ensure that after large disturbances such as circuit breaker trips or load loss, the system remains synchronized and can return to normal conditions. Parallel transient stability was explored in abundance, as they are critical, and the trapezoidal integration met...
The RLC capacities were 0 kW of R-load, −20 kVA of L-load, and 20 kVA of C-load. The test time for anti-islanding of the inverters was recorded when islanding occurred after the circuit breaker oAfpptlh. Secig. r2i0d19s, 9id, xeFsOhRuPtEoEfRf.RTEhVeIEtWime until the ...
REVIEW 9 of 32 Network Network- Network- Network- Network- based based based based Control Loop Control Loop Control Loop Control Loop 12 n-1 n Controller Controller Controller Controller Main Circuit Inverter 1 Main Circuit Inverter 2 AC Bus Main Circuit Inverter n-1 Main Circuit Inverter n ...