likely present in a typical pulse, might begin to become attenuated at the stated bandwidth. That would indicate that we can rely on a 500 MHz bandwidth oscilloscope to show a full and undistorted picture of the input at about 100 MHz, maintaining good fidelity of the signal you...
Ideally, you should use a digitizer with three to five times the bandwidth of your signal as calculated in the equation above. In other words, your oscilloscope’s rise time should be 1/5 to 1/3 of your signal’s rise time to acquire your signal with minimal error. You can always back...
oscilloscope should simplify how you work and shorten the time it takes to find and debug problems. The WaveAce™ combines long memory, a color display, extensive measurement capabilities, advanced triggering and excellent connectivity to improve troubleshooting and shorten debug time. With bandwidths...
16 Analog bandwidth (–3 dB) R&S®MXO 4 with (R&S®MXO 4 -B24x options) 200 MHz, 350 MHz, 500 MHz, 1 GHz, 1.5 GHz Rise time R&S®MXO 4 (with R&S®MXO 4 -B24x options) 1.75 ns, 1 ns, 700 ps, 350 ps, 234 ps Input impedance 50 Ω± 1.5 %, 1 MΩ ± 1 % ||...
海洋兴业科技 HMO2024 2[4] 通道数字时间域 oscilloscope 说明书 H M O 202 4 R 2 G Sa/s Real Time, Low Noise Flash A/D Converter (Reference Class)R 2 M R M SO (Mixed Signal Opt. HO3508) with 8 Logic Channels R S erial Bus Trigger and Hardware accelerated Decode incl...
Rise timeR&S®RTC1002 R&S®RTC-B220/-B221/-B222/-B223)7 ns, 5 ns, 3.5 ns, 1.75 ns, 1.15 ns Input impedance1 MΩ ± 2% || 14 pF ± 2 pF Input sensitivitymax. bandwidth in all ranges1 mV/div to 10 V/div ADC resolution8 bit, up to 16 bit with high resolution-decimation...
Both calibrated vertical sensitivity and calibrated horizontal time are set in 1 - 2 - 5 - 10 steps. This leads, however, to some awkward interpretations of minor divisions 时基控制 增大时基时间/每刻度影响的计算模型 These select the horizontal speed of the CRT's spot as it creates the trace...
Micsig Oscilloscope 1300V 100MHz High Voltage Differential Probe new version DP10013 kit 3.5ns Rise Time 50X/500X Attenuation Model: DP10013Bandwidth: 100MHzRise time: 3.5nsRange selection: 50X-500XAccuracy: About 2 percentMaximum differential test voltage: (DC+AC)130V-1300VMaximum input common...
now, with digital 'scopes, but as far as I can see the manufacturers arrange their waveform reconstruction to give the equivalent result - that's certainly the case with my Tek scope where the risetime is the same as you would have ...
Rise time = 0.35/bandwidth Another common property of Gaussian systems is that the overall system bandwidth6 of the oscilloscope and its probe is the inverse root mean square (RMS) value of their individual bandwidths. The system bandwidth can be calculated using the familiar relationship: ...