Lawrence B G,Crozier S,Cowin G et al.An inverse design of an open,head/neck RF coil for MRI.IEEE Transactions on Biomedical Engineering. 2002Lawrence, B.G.; Crozier, S.; Cowin, G.; Yau, D.D. An Inverse Design of an Open, Head/Neck RF Coil for MRI. IEEE Trans. Biomed. Eng. ...
Retrospective estimation of head-motion between diffusion-weighted images (DWI) acquired within diffusion MRI (dMRI) experiments renders exceptionally challenging1 for datasets including high-diffusivity (or “high b”) images. These “high b” (b > 1000s/mm2) DWIs enable higher angular resolution,...
Cross sections (Supplementary Movie 2 and Fig. 1g~i) of the embryo show that the vasculature was imaged with isotropic spatial resolution throughout the entire 0.5 mm-wide head. The FmFLIM-SLOT system is capable of multiplexed 3D FLIM imaging with up to 4 excitation laser lines, ...
However, MRI offers limited spatial resolution (e.g. 200 × 200 × 1000 μm3 with good contrast) and its use requires the incorporation of specific radioactive labels. In contrast, label-free methods for non-invasive in-vivo or ex-vivo measurements of drug ...
head MRI and had to have a like a hockey helmet on…. the technician did not mind letting me try it on and just sitting there for a few minutes. It takes a lot of patience to work with someone who is claustrophobic.. My MRI was excellent with no problems. ANYONE WHO IS ...
If a patient has been referred for an open MRI it was because they failed to do it in the conventional MRI & if they fail to do this again because of ...
iElectrodes is an open-source Matlab toolbox to localize intracranial electrodes from MRI and CT images. Atlas and brain surfaces can be easily loaded for anatomical labeling. The toolbox is capable of working with ECoG (subdural grids and strips) and SEEG (depth) electrodes. Follow Neural mech...
iElectrodes is an open-source Matlab toolbox to localize intracranial electrodes from MRI and CT images. Atlas and brain surfaces can be easily loaded for anatomical labeling. The toolbox is capable of working with ECoG (subdural grids and strips) and SEEG (depth) electrodes. Follow Neural mech...
MRI data. Analysis of VBM. We found no significant correlations between CIS scores and rGMD or rWMD. Analysis of FA. We found no significant correlations between CIS scores and FA. Analysis of MD. A whole-brain multiple regression analysis that controlled for sex, age, RAPM...
However, since the measured value is actually less than that one expected for a stable 1:1 complex, it should be concluded that, at least in our conditions, a certain fraction of Syn still remains in its free state in solution and that the Syn molecules exchange between the free and ...