ULFM seriesOpen Channel Flow Measurementinstrument is capable of the following functions: High detection accuracy, the flow meter measurement changes with 1mm, the accuracy of change in level is 1 mm; Suitable for a variety of weirs and flumes, Parshall flumes (parshall flume flow meter), Righ...
Structure:Split Type;Measurement Categories:Velocity, Flow, Water Depth, Water Temperature;Level of Protection:IP68;Velocity Measuring Range:The Standard Is 0.04 M/S ~ 5.00 M/S;The Velocity Measurement Resolution:1 mm/S;Water Depth Measurements:0.02 M ~
FM-100V10 Portable digital flow meter open channel flow portable velocity measurement instrument No reviews yet Shenzhen Aermanda Technology Co.,Ltd.2 yrsCN Previous slideNext slide Previous slideNext slideKey attributes Industry-specific attributes type Variable Area Water Flowmeters Other attributes ...
mainly used to measure the flow in sewage plant, enterprise and public institution discharge outlet and urban sewer. The instrument takes the advantage of contactless way as ultrasonic goes through the air, so it keeps higher reliability than other instruments when measuring sticky and corrosive ...
Measurement of water flow in open channels, Part 6.1: Measuring devices, instruments and equipment - Rotating-element current meters (ISO 2537:2007, IDT)doi:AS 3778.6.1:2022AS 3778.6.1:2022同样采用ISO 2537:2007,其中规定了用于测量明渠流速的旋转元件装置的操作要求,构造,校准和维护....
Open channel flow sensors and systems. Water depth and velocity sensors for flow measurement. Area velocity flow meters.
channel. Mainly used to measure the waste water treatment plant, sewage outfall enterprises, the city sewer and water conservancy in the flow channels.As the Company through the air using ultrasonic instruments to non-contact measurement method. Therefore, under ...
1. An apparatus for measuring liquid flow rate, said apparatus comprising: an open channel for carrying a liquid flow, said open channel having an open upper portion, a cross-section of a predetermined width, a bottom wall, and an opening in the bottom wall; ...
www.nature.com/scientificreports OPEN Sodium channel slow inactivation interferes with open channel block received: 16 December 2015 accepted: 20 April 2016 Published: 13 May 2016 Martin Hampl1,2,*, Esther Eberhardt1,3,*, Andrias O. O'Reilly1,4 & Angelika Lampert1,2 Mutations in...
Product Name:Parshall flume River Weir Ultrasonic Open Channel Flow Meter;Measuring range:0.1L/sec~10m3/sec;Ranging range:0~3m;Blind area:0.3m~0.5m;Output signal:4~20mA / RS485;Power supply:220VAC/ 24VDC;Sensor line length:10-50m;Material:ABS;Installatio