Alarm Probe off , low power Modes Visual and Audio Application Adult, Neonate, Children, Pediatric, Big & Small animals NIBP Support big or small animals NIBP measurement range Big Animal Small Animal SYS 40-270mmHg 40-270mmHg MEAN 20-230mmHg 20-230mmHg DIA ...
8 Battery capacity indicatior and prompt when battery low Technical Specifications NIBP Measure Method: Automatic oscillometric Patient: Adult and Pediatric Measurement unite: mmHg/kPa selectable Measurement mode: Manual, Auto, STAT Measurement Type: SYS, DIA, MAP M...
Alarm: Probe off, low power Modes: Visual and Audio Application: Neonatal, pediatric and adult patients NIBP The wider NIBP measurement range Adult PED NEO SYS 40~270mmHg 40~200mmHg 40~135mmHg MEAN 20~230mmHg 20~165mmHg 20~105mmHg DIA 10~210mmHg 10~150mmHg 10~...
SYS : Upper limits70~250 mmHg, Lower limits 60~180 mmHg DIA : Upper limits 40~200 mmHg, Lower limits35~150 mmHg MAP : Upper limits 60~230 mmHg, Lower limits 50~160 mmHg Pulse Rate Range: 0~254 bpm Pulse Rate Accuracy: 1 bpm System specifications Alarm ON/OFF: controlled...
9.Alarm parameter: SYS / DIA SpO2: 1.Measuring range: 0%~100% 2.Resolution:1% 3.Accuracy: 70-100%, ±2%, below 70% unspecified 4.Error in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ...
Alarm parameter: SYS, DIA Inflation: automatic inflation by force pump Deflation: automatic multistep deflation PR: Measure range: 40bpm~240bpm Resolution:1bpm Safety: Power supply: DC 3V (2×1.5V AA alkaline dry battery) Safety type: internally ...
(PC200)Medical/Hospital/ICU Handheld Multiple Parameters Vital Signs Monitor Model:PC200 Parameters:ECG/ETCO2+SPO2+NIBP+TEMP Features 1. The smart and exquisite handheld patient monitor 2. ECG:3/5 Leads, 3 waves 3. Accurate measureme...
Alarm: Probe off, low power Modes: Visual and Audio Application: Neonatal,pediatric and adult patients l NIBP The wider NIDP measurement range Adult Mode SYS 40 ~270 (mmHg) MEAN 20 ~230(mmHg) DIA 10 ~210 (mmHg) Pediatric Mode SYS 40 ~ 200 (mmHg) MEAN 10 ~ ...
Neonatal:SYS:40~135mmHg DIA:10~100mmHg MEAN:20~110mmHg Resolution:1mmHg Measurement Type :SYS,DIA,MEAN Overpressure protection Adult: 300mmHg Pediatric :240mmHg Infant/Neonate :150mmHg SpO2 Measurement range:0~100% ...
Alarm parameter: SYS, DIA Inflation: automatic inflation by force pump Deflation: automatic multistep deflation PR: Measure range: 40bpm~240bpm Resolution:1bpm Safety: Power supply: DC 3V (2×1.5V AA alkaline dry battery) Safety type: internally powe...