Downloads Unterstütztes OS Windows Windows Version 20.1 Preview 20.1 Preview Enthaltene Editionen Full Full Bitanzahl der Anwendung 64 Bit 64 Bit Sprache Englisch Englisch Readme anzeigen NI-XNET Database Editor 20.1 Preview Veröffentlichungsdatum ...
Windows 版本 20.1 Preview 20.1 Preview 包含的版本 完整版 完整版 应用程序位数 64位 64位 语言 英文 英文 查看自述文件 NI-XNET Database Editor 20.1预览版 发布日期 2020/7/23 受支持的操作系统 语言 校验和 文件大小 60.85 MB 产品支持资源 ...
我可以在NI-XNET Database Editor中加载一些DBC或LDF数据库。但是,当我尝试加载特定的DBC或LDF数据库文件时,出现以下错误。 The database specified could not be loaded. Either it does not exist, or it is not a valid XNET database. 指定的数据库无法加载。它不存
An alias is created automatically when you open a new database in the NI-XNET Database Editor. The specified ISO CAN FD mode is used as default, which you can change in the session using this property. Note In ISO CAN FD mode, for every transmitted frame, you can specify in the data...
Figure 6:NI PCI-8513 Software-Selectable (XS) CAN Device In addition, NI ships each of these devices with the appropriate driver software. NI CAN interface driver software is described below. The National InstrumentsECU Measurement and Calibration Toolkitextends the NI LabVIEW, NI LabWindows™/CVI...
NI-XNET 21.0.1 patches the NI-XNET 21.0 release, resolving an issue in which support for PXIe-8623 was unintentionally missing.NI-XNET is an NI instrument driver that features a common set of easy-to-use functions for reading and writing Automotive Ethernet, CAN, LIN, and FlexRay data on...
Insert the NI-XNET software CD into your CD-ROM drive. The installer launches if your CD-ROM drive plays data CDs automatically. If the installer does not launch automatically, navigate to the CD using Windows Explorer and launch theautorun.exefile from your NI-XNET software CD. ...
NI-XNET is an NI instrument driver that features a common set of easy-to-use functions for reading and writing Automotive Ethernet, CAN, LIN, and FlexRay data on many different platforms including USB, PXI, PCI, NI CompactDAQ, and NI CompactRIO. ...
Changed options for building LabVIEW or CVI application installers: "NI-XNET Runtime" installs only the NI-XNET Runtime, "NI-XNET Utilities" installs the NI-XNET Database Editor and Bus Monitor in addition to the NI-XNET Runtime.
710192The NI-XNET Database Editor does not allow you to create a signal with the same name as one that was previously deleted. Avoid this issue by saving the database and re-opening it after deleting the signal. 710389XNET Wait (Transmit Complete) may cause a stale FlexRay frame to retra...