6. Vigorously shake the CF-1 vial to thoroughly mix the solution. Ensure that all of the solution has collected in the bottom portion of the ampoule before carefully breaking open the vial.Note: The CF-1 calibration fluid is supplied in a single use vial. CF-1 must be used within one ...
对于微量 UV-Vis 技术的较新进展,Thermo Scientific™ NanoDrop™ One/OneC型号提供增强的功能(例如,区分核酸样品中的哺乳动物 DNA 和 RNA)以及支持在符合 21 CFR 第11部分规定的实验室中进行合规使用的软件。 此型号的新产品已经停产。如果您将在工作流程中使用荧光技术,请考虑使用Invitrogen™ Qubit™ 4 ...
Multiple samples are saved sequentially in one column. - Spectra, New Workbook (*.twbk) - saves the selected sample data into a new workbook that can be reopened with the NanoDrop 2000/2000c software. - ND Legacy (*.tsv) - saves the absorbance values for corresponding wavelengths along ...
6. Vigorously shake the CF-1 vial to thoroughly mix the solution. Ensure that all of the solution has collected in the bottom portion of the ampoule before carefully breaking open the vial.Note: The CF-1 calibration fluid is supplied in a single use vial. CF-1 must be used within one ...
常見問答集 (常見問題) Yes. While most users will never need to recalibrate their NanoDrop One/Onec Spectrophotometer, we recommend verifying instrument performance using the NanoDrop PV-1 Performance Verification Solution every 6 months. PV-1 is available from the Thermo Fisher website.Ordering...
New sales of this model have been discontinued. Please see the newest model: the NanoDrop One Microvolume UV-Vis Spectrophotometer. Shop Thermo Scientific™ NanoDrop™
NanoDrop Microvolume Spectrophotometer capabilities Advanced sample intelligence With full-spectrum analysis, Acclaro Sample Intelligence software uses advanced chemometric algorithms to identify and correct for contaminants and differentiate DNA from RNA. ...
an extended user manual with troubleshooting section, articles, applications and FAQ. The NanoDrop ND-1000 is provided with a one year warranty, which can be extended and includes the preventive maintenance plans for e.g. calibration, cleaning, alignment of pedestals (the plan can be also ...
Test sample capacity:0.5~2μl;Light source:Xenon lamp;Detector:2048 linear CCD array;Optical path:≤0.7mm;Wavelength range:200~850nm;Wavelength accuracy:<1nm;Wavelength resolution:≤2nm;Light absorption range:0.04~300Abs (10mm);Power:20W;Power Adapter:12
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.Q18: Is PC software included?A18:The PC software(CFR 21 or regular one) is optional. Also the therm...