小鼠血管插管导管有三种常用类型:小鼠颈静脉插管用导管(mouse thoracic jugular vein catheter)、小鼠胸部颈动脉插管用导管(mouse thoracic carotid artery catheter)、小鼠股动静脉插管用导管(mouse femoral vein/artery catheter)。 产品选购: 货号 产品描述
桑戈国际贸易(上海)有限公司主要致力于“Mouse Jugular Vein Catheter for ALZET Pumps 用于ALZET泵的小鼠颈静脉导管 0007700”的生产销售。多年的“Mouse Jugular Vein Catheter for ALZET Pumps 用于ALZET泵的小鼠颈静脉导管 0007700”生产与销售的经验,与各行业新老用
be sure to use infusion equipment designed just for them. The system features our 25ga swivel, which has the lowest rotational friction of any swivel on the market, as part of the mouse Vascular Access Button™ and tether kit. Our 2Fr mouse jugular vein catheter uses PU tubing that has ...
峰源隆國際貿易(上海)有限公司主要致力於“Mouse femoral vein catheter (fvc) for tail cuff小鼠股靜脈導管(fvc)用於尾部袖口 MTC-02”的生產銷售。多年的“Mouse femoral vein catheter (fvc) for tail cuff小鼠股靜脈導管(fvc)用於尾部袖口 MTC-02”生產與銷售的經
When you need to take repeated small blood samples from a mouse, consider placing a catheter in the jugular vein or carotid artery and connecting it to a transcutaneous skin button. This method is a refinement over stress-inducing tail snips, retro-orbital bleeds or other peripheral methods, an...
A method is described for stress-free periodic sampling of blood and/or intravenous infusions in the normal awake and behaving mouse. The surgical procedure consists of the permanent implantation of a Silastic-rubber catheter in the right external jugular vein. The free end of the catheter is ...
Antibodies and fluorescent dyes are usually administered via jugular vein catheter or by the tail vein. Intravital microscopic examination of the various venous thrombosis models is performed immediately after induction of thrombosis and depending on the mod- el usually not longer than 6 h on deeply ...
A catheter approximately 6 cm in length (ID: 0.31 mm, OD: 0.64 mm) (Helix Medical, Inc. CA) was passed subcutaneously from the dorsal to the ventral incision. A 22-gauge needle was inserted into the right jugular vein to guide the catheter into the vein. The catheter was ...
A catheter approximately 6 cm in length (ID: 0.31 mm, OD: 0.64 mm) (Helix Medical, Inc. CA) was passed Neuropsychopharmacology subcutaneously from the dorsal to the ventral incision. A 22-gauge needle was inserted into the right jugular vein to guide the catheter into the vein. The ...
Briefly, a 2-French octapolar mouse electrophysiology catheter was advanced through the right external jugular vein, placing proximal electrodes in the right atrium and distal electrodes into the ri...