The transmission system controlled by traditional droop control has some defects, such as DC voltage deviation, slow dynamic response, fixed droop coeffici
two-stage voltage drop controladaptive voltage rise controlvoltage-dependent active current controlModular Multilevel Converter based High Voltage Direct Current (MMC-HVDC) connected offshore wind farms could suffer serious challenges: DC overvoltage during a fault and post-fault DC voltage restoration. ...
DC model by using PSASP software. It set a single-phase grounding short circuit fault, one two-phase grounding short circuit fault, and a three-phase grounding short circuit fault on the inverting side, and did the simulation study respectively.The simulation results show that the voltage drop ...
(1) By mapping the DC voltage drop at the outlet of the converter station with the ACLC to the voltage drop generated by the equivalent virtual impedance, the pole to pole short-circuit fault circuit can be equivalent to the RLC discharge circuit with virtual impedance, thus the equivalent R...
Toggle Sidebar Find Previous Next of 0 Presentation ModeOpenPrintDownloadCurrent View Tools Zoom Out Zoom In Automatic ZoomActual SizePage FitPage Width50%75%100%125%150%200%300%400%
Figure 1 Schematics of four-terminal MMC-HVDC test bench with DC overhead lines. Full size image Table 1 Main parameters of four-terminal HVDC test bench. Full size table Feature extraction In the HVDC grid, distinct features in current and voltage signals during pre- and post-fault scenarios...
Nominal DC voltage ±50 kV SM capacitance 1500 μF Wind farm rated output 84 MW Length of DC line n 100 km 2.2. Basic control mode The control mode of the MMC at each HVDC terminal and the DFIG is briefly introduced as follows. 2.2.1. MMCs Since the OWF is integrated at T1, AC ...
Power smoothing control strategy for renewable-energy-based DC grid[J]. High Voltage Engineering,2019,45(1):276-283. [34]ZHU M,LI W X,LIANG X D,et al. Stepwise voltage drop and transient current control strategies to enhance fault ride- through capability of MMC-HVDC connected DFIG wind ...