Click on the name of the desired switch. Note: Unless manually configured otherwise as part of a case with Cisco Meraki Support, all switches in a network will be running the same firmware version. MR Series Access Points Navigate to Wireless > Monitor > Access points. Click on the name ...
MX running firmware 18.1 or higher Requires IKEv2 Configuration The FQDN of the Non-Meraki VPN peer can be configured in thePublic IP/Hostnamefield whenIKEv2is the selected IKE version. The default behavior of the MX is to setremote_idto FQDN if it is not explicitly added in the dashboar...
Hi @Eugenijus and welcome to the Meraki Community. The polarization is a characteristic of the physical antennas themselves, so that is not something that can be configured or adjusted. The setting in Dashboard allows you to change the antenna type, depending on what is actually connected to th...
Log in to the new VM and switch to the SDC user. Ensure the SDC is not currently running on the new VM using the command: docker ps If the SDC is running, run the command: sdc stop Confirm that the SDC has stopped running b...
Switch Ports Change: Added "Module" Search Type in "Searching for ports". MS Switch Access Policies (802.1X) Change: Added "Critical Authentication VLAN is only supported in the Single Host, Multi Host, Multi Domain, and Multi Auth modes for Cloud Manager Catalyst switches running CS17 and ...
Network connectivity to the management CPU is broken because Click is not correctly configured to pass traffic to userspace I would really appreciate help debugging this! Switch will DHCP after booting and start an SSH server If you have this hardware and are interested in participating in developm...
When using SNMP v2c and querying any Meraki device (AP, Switch, Firewall, etc) this will produce custom traffic sensors via the counters from the ifXTable. Requirements PRTG version16.2.25or later (Compatibility note) Since theDevice Templaterelies on the auto-discovery process, the device you...
The authentication credentials for a device that uses the default authentication credentials or a device that has not fetched configuration will depend on the firmware version the device is running. MX devices running MX 19+ firmware, MS devices running MS 17+ firmware and MS390/Catalyst...
NTP needs to be enabled on the switch (ntp server {address}), and the switch clock must reflect the correct time. AAA on the switch must be configured using aaa new-model. RADIUS authentication is not currently supported. SSH access to the switch CLI must be enabled and accessib...
This only happend to the ports connected to AP's. The switch is only used for AP's, but none of the unused ports were disabled. All ports are configured as a trunk port; RSTP: enabled; STP Guard: disabled. POE: enabled Link: Autoneg Schedule: unscheduled Isolation: dis...