MICROELECTRODE MEASUREMETS OF MEMBRANE RESISTANCE AND CAPACITANCE IN THE SARTORIUS MUSCLE OF THE TOAD (BUFO MARINUS)ELECTROPHYSIOLOGYEXPERIMENTAL LAB STUDYMUSCLESTOADSElectrical impedance measurements using two inserted microelectrodes have confirmed that the properties of the toad sartorius muscle fibre, over ...
Membrane resistance and capacitance structure 翻译结果2复制译文编辑译文朗读译文返回顶部 正在翻译,请等待... 翻译结果3复制译文编辑译文朗读译文返回顶部 Raised resistance-capacitance of the membrane structure 翻译结果4复制译文编辑译文朗读译文返回顶部
The membrane resistance and capacitance are calculated from the whole impedance spectrum, which is said to be more informative for the characterization of lipid membranes compared to capacitance and resistance calculated at certain frequencies [12]. The time course of membrane capacitance of these two ...
and the electrodes on both sides of the membrane also have a certain resistance. The properties of the ion-exchange membrane, the solution, and the electrodes can be described electrically by an equivalent circuit as indicated inFigure 3.11, where Cmand Rmare the membrane capacitance and ...
Resting potentials of excitable cells in the petiole and main pulvinus of Mimosa pudica depended on the external concentrations of potassium ([K$]) and sod... S Michikazu,S Takao - 《Plant & Cell Physiology》 被引量: 90发表: 1982年 An anatomical basis for the resistance and capacitance in...
Thread starter granpa Start date Sep 21, 2008 Tags Cell Membrane Resistance In summary, myelin significantly increases resistance across the cell membrane and decreases capacitance, resulting in a 5,000-fold increase in resistance and a 50-fold decrease in capacitance. This decrease in capacitance...
equations may be the use of BIS resistance parameters, either as the resistances (R) or as the so-called resistance indices (RI) [11–13]. The resistances are calculated directly from the measured BIS data, while the resistance indices are calculated from the resistances and the subject’s ...
when the series in the polarization voltage and the resistance R between the diaphragm and electrostatic for - Electro-acoustic transducer capacitance Co posed by the membrane time constant is much larger than the cycle frequency vibration, such Diaphragm uneven surface charge distribution of the situat...
differential-input capacitance differential-input impedance differential-input measurement differential-input resistance differential-input voltage differential-mode gain differential-mode input differential-mode signal differential-pressure fuel valve differential-pressure gage ...
The membrane capacitance and resistance measurements were observed to depend on the concentration and the applied frequency of the electrolyte. The observed capacitances and resistances were used to calculate the membrane resistances (RM), capacitance (CM), reactance (XX), and also derive the ...