cardiac catheterization laboratories combining advanced imaging and capabilities for both surgical and interventional procedures has increased dramatically mainly due to their need for the realization of transcatheter aortic valve replacement (TAVR), one of the fastest growing procedures in the United States....
A transcatheter pulmonary valve (Melody®) was implanted within a stenotic biological valve prosthesis in tricuspid position, as an alternative to the fourth major cardiac surgery in a 12-year-old girl. There were no complications. The postinterventional result was very good. © 2012 Wiley Per...
• Code 33477 includes all cardiac catheterization(s), intraprocedural contrast injection(s), fluoroscopic radiological supervision and interpretation, and imaging guidance performed to complete the pulmonary valve procedure. Do not report 33477 in conjunction with 76000, 76001, 93451, 93453, 93454, 93...
Pulmonary valve implantationCardiac catheterizationBackgroundPercutaneous implantation of pulmonary valves has recently been introduced into clinical practice. AimTo analyse data of patients treated in France between April 2008 and December 2010. MethodsProspective, observational, multi-centric survey by means ...
Seven patients had early interventional cardiac catheterization to relieve severe right ventricular outflow tract obstruction. Twenty-four patients had surgical valve replacement (six urgently; nine semi-urgently; nine electively). Staphylococcus aureus IE required surgery in all but one patient. Three ...
An Electro-Mechanical Model of the Heart for Cardiac Image Analysis We present a 3D numerical model of the heart ventricles which couples electrical and biomechanical activities. We have adopted a simpler formulation of pre... M Sermesant,Y Coudière,H Delingette,... - IEEE 被引量: 66发表...
Sumski, Christopher A.Childrens Hosp WisconsinBartz, PeterChildrens Hosp WisconsinGudausky, ToddCatheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions
A Hybrid Melody valve insertion was planned. Due to the low weight, the risk of left ventricular outflow tract obstruction was significant and therefore evaluated preprocedurally using a cardiac computed tomography鈥揹erived 3-dimensional printed model. In vitro tests showed good anchorage of the ...
Radiation exposure by three-dimensional rotational angiography (3DRA) during trans-catheter melody pulmonary valve procedures (TMPV) in a pediatric cardiac catheterization laboratory. Pediatr Cardiol. 2016;37:1429. doi:10.1007/s00246-016-1453-0....
CARDIAC catheterizationHEART valve prosthesis implantationTRANSLUMINAL angioplastyTHORACIC aortaTRICUSPID valveBIOPROSTHETIC heart valvesHEART ventriclesIN situ hybridizationDziewulska, AleksandraMoszura, TomaszMeyer-Szary, JarosawKordon, ZbigniewMroczek, Tomasz...