im new to matlab and even more to app designer but i need to make an app with a UIAxes and a discrete knob, since i have a very long code and uploading it here i'm sure would be painful and boring for y'all i'll make an example of my problem....
You can now perform further analysis with the reduced model. For example: Examine other responses of the reduced system, such as the step response or Nichols plot. To do so, use the tools on the Plots tab. See Visualize Reduced-Order Models in Model Reducer App for more information. Export...
LOC may be either a 1x4 position vector or one of the following strings: 'North' inside plot box near top 'South' inside bottom 'East' inside right 'West' inside left 'NorthEast' inside top right (default for 2-D plots) 'NorthWest' inside top left 'SouthEast' inside bottom right '...
Modeling or system modeling is the study of the model for evaluating or examine or for analysis of systems behavior against the input. With the help of modeling, we can modify our system, we can reduce the cost of the system, and we can make our system more effective and efficient. ...
You acquire and visualize real-time data from mixed sources and perform interactive analyses with minimal effort and no coding. You trigger specific signals and test profiles. You create instrument panels that make it easier to interact with your test application, or tweak parameters to influenc...
Use the Response Time slider to make the closed-loop response of the control system faster or slower. To change the limits of the slider, drag the slider to the left or right end. To decrease or increase the response time by a factor of 10, click or . Use the Transient Behavior slider...
cbFunc = @(hSlider,evtData)set(hContour,'ContourZLevel',hSlider.getValue/100*zrange+zmin); hjSlider.StateChangedCallback= cbFunc;% set the callback for slider action eventscbFunc(hjSlider,[]);% evaluate the callback to synchronize the initial display Interactive contour height...
rpmtrack(___) with no output arguments plots the power time-frequency map and the estimated RPM profile on an interactive figure. exampleExamples collapse all RPM Profile of Vibration Signal Generate a vibration signal with three harmonic components. The signal is sampled at 1 kHz for 16 seconds...
integrates the ODE system from the initial values given in init to make state predictions. If data is a struct, init is ignored and assumed to be a field of data.out = GMGTS(_, Plot=false, ...) disables plots with parameter estimates, the inferred random effects distribution, model pred...