可以尝试修改模型的名称,我刚遇到这种情况。就是因为模型的名称和StateFlow中的一个数据同名。警告还是小事,但是当生成代码的时候,就会直接报错。
如果:The block diagram 'three_phase_inverter_pwm' uses bus signals. However,the 'Mux blocks used to create bus signals' diagnostic is not configured to 'error'. To prevent modeling errors:(1) Open Upgrade Advisor and run the 'Check for Mux blocks used to create bus signals' ...
报错: The "VariableStepDiscrete" solver cannot be used to simulate block diagram ' xx’ because it contains continuous states 原因: simulink的求解设置默认下为discrete离散求解。 解决方案: Ctrl+E,打开设置菜单,将求解器方案改为auto,这个时候,就算simulink包含连续的模块也可以进行求解了。编辑...
block_diagram does not have a parameter named 'Kp This is the result . i got when i am running the code for fractional order pid controller Kindly reply 0 Comments Sign in to comment. Melihon 5 Dec 2023 0 Link Save models, bdclose all, reopen model ...
用matlab进行仿真,出现错误了,怎么解决 如果: The block diagram 'three_phase_inverter_pwm' uses bus signals. However, the 'Mux blocks used to create bus signals' diagnostic is not configured to 'error'. To prevent modeling errors: (1) Open Upgrade Advisor and run ...
编译时出现如下错误: Error in'keshe/ ':Initialization commands cannot be evaluated. Caused by: The diagram must contain a powergui block. The block should be named 'powergui'and should be located at the highest levelof your diagram where SimPowerSystems blocks are found.Component: Simulink | Cat...
There is a "block diagram error" while compiling a simulink control strategy model to .dll file.Without any other hints and cannot find where the issue is.This model is going right when simulation in simulink.If someone can help me, thanks for your kindness. 0 Comments Sign in to comment...
1、首先在电脑中打开matlab,打开simulink,如图所示。2、接着创建一个空的模块,如下图所示。3、这里会有一个模块的库,里面各种需要的模块(这里默认对simulink有一定基础),选用自己需要的进行搭建。4、对积分模块进行初始化,其格式为[1 1]可以更多维,也可以单个维度,但是多维时要正确填写格式,...
另一种错误是在使用电压测量时报的错误: Error evaluating 'InitFcn' callback of Voltage Measurement block (mask) 'Voltage Measurement'. Error using ==> get_param block_diagram does not have a parameter named 'PortConnectivity' 给出的解决方法: ...