A luminol based chemiluminescent trimeric system, namely 2,3-dihydro-5,8-di(thiophen-2-yl)phthalazine-1,4-dione (T2B-Lum), bearing thiophene rings as donor units and 2,3-dihydrophthalazine-1,4-dione as an acceptor unit was synthesized in two steps via donor-acceptor-donor approach using ...
A BAS-100A Electrochemical Analyzer (Bioanalysis System Inc., USA) is used as a potentiostat to exert the electrolytic potential with a self-designed digital-pulse-generator as the outer pulse source. Fluorescence measurements are carried out on an F-4500 Fluorescence Spectrophoto-meter (Hitachi, ...
Chitosan -induced Au/Ag nanoalloys in the coumarin derivatives intensified-luminol CL system, in addition to catalyze CL reaction can make a change in the process of coumarin derivatives effect as fluorophore on the luminol CL system. This phenomenon is caused by interaction between active functional...
发现了Luminol-Cu(Ⅱ)-维生素B2化学发光体系,探讨了影响化学发光反应的各个因素,建立了测定维生素B2的流动注射化学发光新方法.该方法的线性范围为2.0×10-8-2.0×10-6g/mL,检出限为8×10-9g/mL,相对标准偏差为2.3%(2.0×10-7g/mL,n=11).该方法已用于药物制剂中维生素B2含量的测定.关键...
The optimal CL system consisted of 0.1 mol·L-1 NaOH,4.0×10-4 mol·L-1 luminol,6.08×10-5 mol·L-1 AuNPs and 1.0×10-3 mol·L-1 HgCl2.Under the selected experimental conditions,the linear range was 2.0×10-9-1.0×10-7 g·mL-1(r=0.9929)with the detection limit of 1.5×10-9...
A dual-potential ratiometric electrochemiluminescence cytosensing system is constructed.Functionalized carbon nitride nanosheets are synthesized for improv... Y Feng,S Feng,L Chen,... - 《Journal of Electroanalytical Chemistry》 被引量: 2发表: 2016年 Ratiometric Electrochemiluminescent Immunoassay for Tumo...
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol-AgNO3-Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. ...
Using 3-aminopropyl-triethoxysilane as an effective enhancer, the ECL system can detect Hg2+ ion within a linear range from 2.0×10−10 mol L−1 to 2.0×10−8 M, with a detection limit as low as 1.05×10−10 M (3σ). Moreover, this ECL system is highly specific for...
鲁米诺-过硫酸钠体系后化学发光法测定银吴雄志王啸吕晓惠桂林理工大学化学与生物工程学院,桂林541004摘要:邻菲罗啉存在下,银对鲁米诺-Na2S2O8体系的后化学发光具有增敏作用,建立了流动注射后化学发光测定银的新方法。在优化实验条件下,该法测定银的线性范围为1.0×10-9~4.0×10-7 mol/L,线性相关系数为0.9987(n ...
Based on a specially designed flow-through ECL cell with a very simple structure, the system possesses rapid response and high sensitivity. With luminol as the ECL reagent, the response of hydrogen peroxide (H2O2) was investigated on the developed FIA-ECL system. After optimizing the experimental...