好办,用Analysis group。用最通俗易懂的话来解释Analysis group就是,Analysis group可以让用户自定义一个Monitor,你可以定义这个monitor去监测average transmission,也可用它去监测band structure(lumerical内置),你甚至可以定义它去监测接下来一个星期的天气,开个玩笑。这一切的关键在于你怎么定义,接下来,我将以average ...
lumerical analysis group的用法 以下是20个关于“lumerical analysis group”的双语例句: 1.我最近一直在研究Lumerical Analysis Group提供的工具,难道你不觉得它们超级强大吗?I've been studying the tools provided by Lumerical Analysis Group recently. Don't you think they are super powerful? 2.我们小组在...
其中修改了轴标签:ref_analysis_EME_analysis_neff.jpg绿线表示 neff 的虚部,对应于损失,蓝线表示 ne...
If you're facing engineering challenges, our team is here to assist. With a wealth of experience and a commitment to innovation, we invite you to reach out to us. Let's collaborate to turn your engineering obstacles into opportunities for growth and success. Contact us today to start the ...
Lumerical's scripting language allows you to automate tasks and analysis such as manipulating simulation objects, launching simulations, and analyzing results. Script commands can be entered directly into the script prompt, run from a saved script file (.lsf), or used within some simulation objects...
分析光线条数(# Analysis Rays):5000(减少光线条数可增加光线追迹速度)。 探测器 数据类型(Data Type):1 PSF模式波长(PSF Wave#):2 再次打开光线追迹控制(Ray Trace Control),并再次运行光线追迹。在探测器查看器中,将显示数据(Show Data)设置更改为相干照度(Coherent Irradiance): 如您所见,序列模式下的惠...
addanalysisgroup addanalysisprop addanalysisresult addassemblygroup addattribute addbandstructuremonitor addbc (deprecated, see other add boundary conditions command, such as addvoltagebc) addbulkgen addchargemesh addchargemonitor addchargesolver addcircle addcontact (deprecated, see addelectricalcontact) add...
from high-performance curvilinear shape generation with CurvyCore-based PCells to entire system-level thermal and EM analysis,” notes Glen Clark, corporate VP research and development in the Custom IC & PCB Group at Cadence. “The PDK incorporates the Cadence schematic and layout-driven photonics...
To recalculate results for a longer taper, go to the CELL GROUP DEFINITION section of the EME Analysis window and change the GROUP SPAN of the second cell group region. Change this from 10um to 100um, which will correspond to the same device geometry but now with a 100um long taper regi...
If you're facing engineering challenges, our team is here to assist. With a wealth of experience and a commitment to innovation, we invite you to reach out to us. Let's collaborate to turn your engineering obstacles into opportunities for growth and success. Contact us today to start the ...