1.OFF 为最高等级 关闭了日志信息 2.FATAL 为可能导致应用中止的严重事件错误 3.ERROR 为严重错误 主要是程序的错误 4.WARN 为一般警告,比如session丢失 5.INFO 为一般要显示的信息,比如登录登出 6.DEBUG 为程序的调试信息 7.TRACE 为比DEBUG更细粒度的事件信息 8.ALL 为最低等级,将打开所有级别的日志 输出...
The user is logging off and ending the current user session. 用户正在注销并结束当前用户会话。 msdn2.microsoft.com 9. NO! Dude if you can't let this go, I'm logging off right now. 不要!喂如果你不能放下这件事,我现在就登出。 forum.gamer.com.tw 10. Windows Logon screen for logging...
this message, the log-off operation is canceled. If your application handles theWM_QUERYENDSESSIONmessage, you can allow the user to cancel the log-off operation, even if another application or the system originated the end-session request. For an example, seeHow to Log Off the Current User...
An open application or process prevents the user session from logging off.When Windows logs off, it attempts to close all open user applications. If an application is either hung or presents a dialogue box requesting user input, the default behaviour of Windows is to prompt the user on how ...
off turn off logging severe log.severe("...") a major failure which prevents normal program execution, e.g. a web-app failing to start or a server restart warning log.warning("...") a serious issue, likely causing incorrect behavior, like a 500 response code to a browser info log.in...
This variable controls whether logging to the binary log is enabled for the current session (assuming that the binary log itself is enabled). The default value is ON. To disable or enable binary logging for the current session, set the session sql_log_bin variable to OFF or ON. Set this...
oflog_statementwill not be logged again after their execution duration exceeds the value of this parameter. If you are not usingsyslog, it is recommended that you log the process ID (PID) or session ID using log_line_prefix so that you can link the current statement message to the last ...
The third mandatoryNameValPairelement toggles this log-handler on and off. This element contains a statementParamName="LOG_STATUS", with a value ofOnorOff, as follows: <NameValPair ParamName="LOG_STATUS" Value="On" /> Finally, within the opening and closingValNameListtags, if you specifyFil...
none of the handlers will receiveINFOlevel events. When you set a log level on the handler, the restriction only applies to that handler and not the others. For example, turningDEBUGoff for the File Handler means noDEBUGmessages will be written to the log file, however,DEBUGmessages will be...
Do not start two browser sessions from the same client computer. The two sessions are regarded as one session, which might affect data integrity. To log in: Procedure