The complex load-bearing behaviour of masonry shows that the analysis of flexural wall panels using the yield line theory depends on the axial load and the material strength of the units and mortar, as well as their bond. To consider these different residual load-bearing capacities, a new non...
Keywords:autoclavedaeratedconcrete(AAC):lpad—bearingmasonrywall(LMW);seismicbehavior;construe— tiona1column;concretestrip Comparedwithclaysolidbricksandconcreteho1. 1owblocks.autoclavedaeratedconcrete(AAC)blocks areeasiertoprocess。andtheyhavesmallervolumeden— ...
Wind, earth pressure, and earthquakes acting on a building generate bending effects and produce shear stresses in load bearing masonry walls. Stress and strain responses during shearing of masonry joints indicate unrecoverable shear and normal deformation that demand use of a constitutive model specifical...
[Also in Division F2] A load-bearing partition or wall includes a structural member comprising a skeleton which is covered on both sides by a cladding and which consists of a substantially rectangular outer frame 1 formed by a continuous tubular metal section 2, 3 the frame being reinforced ...
3.1.4.3.7 Integrity of masonry building In masonry buildings, the integrity between all structural elements including foundation, roof, and load-bearing walls must be provided appropriately with horizontal and vertical ties according to criteria presented in the first section “masonry buildings with tie...
This type of damage can prevent the evacuation of people from the buildings during the earthquake, as the falling masonry elements block the evacuation routes, and hinder the reoccupancy and functional recovery of affected buildings after an earthquake. The authors recognize that both loadbearing and...
The 10 reinforced concrete masonry columns have been tested under eccentric load.The bearing capacities,the load-deformation relationship,the failure process and mode have been studied.The influence factors to the bearing capacity are considered,such as eccentricity,the rebar in the button stem,and the...
In general, the FRP plate is locally strengthened by steel or FRP end tabs where it is bolted through into the anchorage zone, to avoid local bearing failure or splitting of the FRP plate during the prestressing process, and also in the long-term once it is anchored. ...
Slender load-bearing masonry walls are typically used in low-rise commercial and industrial settings, where they are an efficient system to resist out-of-p... C Pettit,C Cruz-Noguez - American Society of Civil Engineers 被引量: 0发表: 2021年 Seismic Behavior, Evaluation, and Retrofit of Old...
3) non-bearing masonry walls 非承重砌体墙 1. Based on the test results of typical seismic bearing capacity of non-bearing masonry walls,the applicability of ANSYS is studied. 应用ANSYS对非承重砌体墙进行非线性有限元分析,并与试验作比较,论证ANSYS对于砌体结构分析的适用性。 2. The nonlinear ...