The complex load-bearing behaviour of masonry shows that the analysis of flexural wall panels using the yield line theory depends on the axial load and the material strength of the units and mortar, as well as their bond. To consider these different residual load-bearing capacities, a new non...
Yu J inghai et日, Experimental Study on Improving Seismic Behavior of Load-Bearing Masonry Wall Made of AutoclavedAerated Concrete 1 0 ~ \ / \ / 9西 — 8---. 6 l ,、 3 / \ 、 4 //5 、 , ll \, 4 V 几 ^ , \ 12 , ...
3.1.4.3.7 Integrity of masonry building In masonry buildings, the integrity between all structural elements including foundation, roof, and load-bearing walls must be provided appropriately with horizontal and vertical ties according to criteria presented in the first section “masonry buildings with tie...
under section 41(3) of the BO, as the removalofanon-load bearingblockwallwillonly reduce the loading in a particular flat unit, and will not [...] legco.gov.hk legco.gov.hk 由於拆除 非承重磚造牆只會減輕某一單位內的苛載,並且不會對建築物的結構安全構成任何主要的負面影響,因此這些牆壁的...
A precast concrete cladding wall system has some advantages with respect to the traditional non-load bearing masonry claddings. Studies on improving the performances of traditional masonry claddings under blast loads are presented in [33], [34], while in [35], the load bearing capacity of load...
The Masonry Design add-on for RFEM allows you to design masonry using the finite element method. It was developed as part of the research project titled DDMaS – Digitizing the Design of Masonry Structures. The material model represents the nonlinear behavior of the brick-mortar combination in ...
29、8 (39) 712 (37)AThe weights given in the table are for scored tile. If any of the faces are unscored, the weights shall be increased 0.5 lb/ft2(2.4 kg/m2) of unscored area.C5610211. Keywords11.1 clay; masonry construction; nonloadbearing tile; physi-cal properties; shale; tileSU...
it is common to make one building portion in such a manner for manufacturing and warehousing and add another portion of the building such as an office portion having masonry walls. The masonry walls, whether they be load bearing or erected together with steel columns and horizontal beams, necess...
The precompression value of 0.62 N/mm2 was kept constant throughout the lateral load test to simulate the vertical compression endured by a load-bearing wall at the base of a three-story building. The lateral load was applied to the plane of the wall, at the top on the vertical side of...
artificial neural network;steel shear wall;finite element method;opening;radial basis function 1. Introduction Walls have been utilized in construction not only as a barrier (i.e., basement walls) [1,2] or infill (i.e., infill masonry walls) [3,4] but also as a lateral load-bearing sys...