Arkundato A, Su'ud Z, Mikrajudin A and Widayani January 2013 Study of liquid lead corrosion of fast nuclear reactor and its mitigation by using molecular dynamics method, International Journal of Applied Physics and Mathematics 3. 1 Singapore...
The composition profiles of the corroded layers have then been assessed semi-quantitatively by Glow Discharge –Optical Electron Spectroscopy (GD-OES) using the Horiba Jobin–Yvon GD-Profiler 2 in the radio-frequency mode (30 W and 800 Pa). The corrosion coupon is first cleaned from remaining ...
The annealed actuators were then coated with a 1-μm-thick layer of Parylene-C to prevent corrosion in the aqueous testing envir- onment and to provide in vivo biocompatibility62 (Figure 5g). The as-fabricated actuators (prior to annealing) and the annealed actuators are shown in Figure 6....
Corrosion mitigation system for liquid metal reactors equipped passive decay heat removal systemA liquid metal nuclear reactor is described. The reactor includes a concrete reactor silo, and at least one primary vessel located in the reactor silo and coupled to a reactor shield deck. Each primary ...
Corrosion mitigation in desalination plants by ammonium-based ionic liquid.doi:10.1038/S41598-021-00925-ZM. A. DeyabQ. MohsenSpringer Science and Business Media LLC
PURPOSE: A liquid metal reactor provided with a passive natural circulation decay heat removal system is provided to be capable of preventing corrosion due to humid salt-included air and a significant loss-of-coolant accident even in the case of double vessel rupture. CONSTITUTION: A reactor ...
CuNi alloy corrosion in sulfide-containing seawater is the fundamental problem in the desalination industry. Here we have confronted this difficulty by using ammonium-based ionic liquid (Diethyl (2-methoxyethyl)-methyl ammonium Bis(fluorosulfonyl)imide) [DEMEMA][FSI]. The results revealed that the [...
The corrosion rates of amines are considerably less than the ionic liquids, but the combined effect of both the solvents has a weight percent threshold limit. Extreme corrosion rates are expected and advanced corrosion mitigation techniques must be considered for the process design Usually commercial ...
Green mitigation of microbial corrosion by copper nanoparticles doped carbon quantum dots nanohybrid. Environ. Sci. Pollut. Res. 2020, 27, 40537–40551. [Google Scholar] [CrossRef] [PubMed] Dinca, I.; Ban, C.; Stefan, A.; Pelin, G. Nanocomposites as Advanced Materials for Aerospace ...
liquid metal blankets; magnetohydrodynamics (MHD); tritium; corrosion; convection; turbulence; WCLL blanket; DCLL blanket 1. Introduction As stated in the most recent European roadmap for a DEMO reactor [1,2], one of the candidate driver blankets that will be investigated in ITER is the ...