Connect the magnetostrictive level transmitter as shown in the above image. Take the datasheet of the particular level transmitter. In the datasheet, you will find lower range value (4mA) and upper range value (20mA). Example: LRV is 5 inch and URV is 20 inch. If you don’t have the...
If not, do zero adjustment at transmitter using HART Communicator Apply water level until 100% marking on chamber *Multimeter should show 20mA *If not, do span adjustment at transmitter using HART Communicator *Verify the linearity by increasing and decreasing the pressure (0%,25%,50%,75%,100...
2.4.1 Make sure you are connected to the correct transmitter Verify that the serial number on the label matches the one in your configuration tool. Procedure 1. Write down the serial number from the transmitter label. 2. Verify the same serial number in your configuration tool. • Rosemount...
level transmitterhydrostatic level transmitter4-20ma level transmitterHeidenhain new original linear encoder LS487C 1040 5.0 C001 ID 572249-17 optical grating rulerFactory Supply High Stability Magnetostrictive Linear Displacement Sensor for Injection Molding MachineMIRAN manufacturer KTC1( LWH)-500mm Linear ...
CAPVEL-ICT Capacitance Level Transmitter INSTRUCTI CAPVEL-ICT Capacitance Level Transmitter
41 14. Transportation And Storage To prevent the EAX30400-C Ultrasonic Level Transmitter from damage during the transportation, please keep the packaging condition as how it was when it was shipped from the factory before arriving at the installation site. The storage conditions should meet the ...
Protection Grade Transmitter: IP65, Sensor: IP68 Relay 2 ways relay Packaging and delivery Selling Units: Single item Single package size: 33X30X20 cm Single gross weight: 6.000 kg Show more Samples Maximum order quantity: 1 piece Sample price: $900.00/pieceOrder sampleKnow...
A level measuring method is specified, having a hot-wire measuring device in which a hot-wire transmitter (5) is supplied with a predetermined constant current, and a voltage rise is detected via the hot-wire transmitter within a predetermined time. …In this case, errors caused by ...
Display Type Level Transmitter Accuracy Grade 0.5G IP Rating IP65 Certification CE ISO9001 Customized Customized Application Liquid Ambient Temp -30ºC~80ºC Ambient Humidity less than 95%RH Supply 220VAC,18-36VDC (optional) Output SPDT...
the level of the magnet within the float & transmit the data back toward the control system. This switch includes buoyancy, electronics & magnetostriction to measure liquid levels. A liquid float moves up & down because of its buoyancy that is mounted on the stem of the level transmitter. ...