A new statistical enhanced multioffset phase analysis of surface wave data is presented. The phase processing of point receiver land data allows identification of velocity variations with a lateral resolution equal to the receiver spacing. An automatic procedure is set up to identify sharp lateral ...
(-r2/2s2). The resolution in this direction is then usually defined as the width of the response function between 14% and 86% of the curve, which corresponds to two standard deviations from the mean of probabilities (2s statistical criterion). More commonly, the resolution is obtained with ...
where SFu˙ and SFu¨ are the cross spectral densities between the force and the treadmill velocity (with amplitude u˙0) and acceleration (with amplitude u¨0) respectively, whereas Δf is the frequency resolution of the spectra. In Fig. 16, the results from the experimental campaign are sh...
The lateral resolution is improved by compensation using a factor of ~ 220. Notably, the described method compensated for only near-surface lateral-heat-conduction effects. In21, a digital micromirror device (DMD) chip was combined with a near-infrared (NIR) laser to achieve a high-power...
Lysogenic induction ends the stable association between a bacteriophage and its host, and the transition to the lytic cycle begins with early prophage excision followed by DNA replication and packaging (ERP). This temporal program is considered universal
Then, the high-quality sequences were denoised using the DADA287 plugin of the QIIME288 (version 2020.2) pipeline with recommended parameters, providing single-nucleotide resolution based on error profiles within samples. DADA2 denoised sequences are usually called amplicon sequence variants (ASVs)....
Resolution: 508dpi. No Colour Correction was applied. The film piece was placed at the central position on the scanner bed and on the other materials used as substitute scanner beds to ensure the whole film piece is in the scanning area. Each film piece was scanned 5 times. The scanned im...
Consequently, the photodetector 37 signal level is generally increased for the first or second reading device 26, 41, which may enable resolution of smaller changes in the optical transmission of test/control regions 5, 18 (FIG. 13). It has been surprisingly found that this may result in ...
Volumetric measurement of the lateral ventricle using high-resolution magnetic resonance imaging (MRI) by Allen et al.8 revealed site- and sex-related variations. In both males and females, the right lateral ventricle was significantly larger than the left. Range and mean were also generally greate...
Kerwin Kwek Zeming1,2,3,*, Thoriq Salafi1,2,4,*, Chia-Hung Chen1,3 &Yong Zhang1,2,4 Deterministic lateral displacement (DLD) method for particle separation in microfluidic devices has been extensively used for particle separation in recent years due to its high resolution and ...