However, adaptive bed leveling is a bit different. The idea is that the printer only probes the area where the part is going to print. If your print bed is 235 mm x 235 mm but your part is 50 mm square, you could just probe the points under the 50 mm square. ...
## Custom bed mest probes ## Prusa has 3x3 or 7x7, you can do any variation you want # [bed_mesh] # probe_count: 4,4 # Linear correction # Check `extruders/linear-correction` for more informations. [include klipper-prusa-mk3s/extruders/linear-correction/linear-correction-0.cfg] # Defa...
If not, then you probably want to move the probe up or down to fix this. You want it to trigger well before the nozzle hits the bed, so that possible stuck filament or a warped bed doesn't affect any probing action. But at the same time, you want the retracted position to be ...
TURN_OFF_HEATERS CANCEL_PRINT_BASE [gcode_macro _TOOLHEAD_PARK_PAUSE_CANCEL] description: Helper: park toolhead used in PAUSE and CANCEL_PRINT variable_extrude: 1.0 gcode: ### set park positon for x and y ### # default is your max posion from your printer.cfg {% set x_park = print...
Klicky probe does not do unnecessary docking/undocking during start of print. At the beginning of the print the printer waits until the chamber is hot and measures it with a hotend thermistor, no extra thermistor needed. I have a table translating the filament name to the desired chamber temp...
Your printer shouldn't have any crashes due to the movement patterns used, and re-homing before/after each test, so it's safe to walk away and let it do it's thing. Using Ellis' pattern (AUTO_SPEED_VALIDATE) isNOTa safe movement pattern. Please ensure your toolhead isn't crashing be...
If the MESH_MIN and MESH_MAX arguments are provided to PRINT_START it will automatically use this for bed mesh calibration (so long as a [bed_mesh] section is detected in your config). The following additional configuration options are available from globals.cfg. variable_probe_mesh_padding ...
and position_endstop define locations on the linear rail controlling the axis. Setting a position_min is setting a limit on the rail, not on the distance between nozzle and head. I understand that this can be confusing - in particular when using probe:z_virtual_endstop. I suspect better ...
rename_existing: CANCEL_PRINT_BASE variable_park: True gcode: ## Move head and retract only if not already in the pause state and park set to true {% if printer.pause_resume.is_paused|lower == 'false' and park|lower == 'true'%} ...