About the Kinetix 5700 The Kinetix 5700 drive modules are zero-stacked and use the shared-bus Servo Drive System connection system to extend power from one drive module to another. Systems are designed to support Integrated Motion over the EtherNet/IP network. Table 3 - Kinetix 5700 Drive ...
Zero-stack Tab and Cutout Engaging the zero-stack tab and cutout from module-to-module is required for shared-bus drive systems and includes the Kinetix 5700 accessory modules. This is done to make sure that the module connectors are spaced properly to accept the shared-bus connection system....
The Kinetix® 5700 DC-bus (converter) power supply with 400V-class three-phase AC input provides continuous output power and current to servo drives for applications with requirements in the range of 7…46 kW and 10.5…69.2A, respectively. For additional output power (kW) you can install ...
Table 38 - Module State Status Indicator Status Indicator Off Flash red/green Flashing green Steady green Flashing red Steady red State Power off Drive self-testing Standby Operational Major recoverable fault Major nonrecoverable fault Rockwell Automation Publication 2097-UM002E-EN-P - December 2022 ...
5 Drive Enable input must be opened when main power is removed, or a drive fault occurs. A delay of at least 1.0 second must be observed before attempting to enable the drive after main power is restored. 6 Cable shield clamp must be used to meet CE requirements. No external connection ...
capacitormodule,publication2198-IN004. IMPORTANTToimprovesystemperformance,runwiresandcablesinthewirewaysas establishedinChapter2. ConnectionstotheDCbusand24Vcontrolpowermustbemadewiththe shared-busconnectionsystem. Figure45-CapacitorModuleWiring Kix5500CapacitorModule TopView 2 3 ItemDescription 21 14 1Modulesta...
97 Updated controller configuration by adding GuardLogix controller and ControlLogix EtherNet/IP 105 communication module configuration. Broke out Configure the Kinetix 5500 Drive with separate procedures for 2198-Hxxx-ERS and 110 and 112 2198-Hxxx-ERS2 servo drives. Updated Tune the Axes with a ...
(MF) connector - A 12 Module status indicator 21 Motor brake (BC) connector - A 4 Motor feedback (MF) connector - B 13 Network status indicator 22 Motor power (MP) connector - A 5 Universal feedback (UFB) connector - A 14 LCD display 23 Motor power (MP) connector - B 6 ...
The contactor-enable relay helps protect the DC-bus power supply in the event of shutdown fault conditions. • The DC-bus conditioner module is required when the combined motor cable length exceeds 400 m (1312 ft) and/or when the AC input-power source type is impedance-grounded. Other ...