To configure the J-Link/J-Trace adapter for debugging: Open the Options for Target ... — Debug dialog of µVision. Enable Use and select Cortex-M/R J-LINK/J-Trace. Click Settings to open the Target Driver Setup dialog. Select SW (Serial Wire) for the
Open the Options for Target ... — Debug dialog of µVision. Enable Use and select Cortex-M/R J-LINK/J-Trace. Click Settings to open the Target Driver Setup dialog. Select SW (Serial Wire) for the debug Port, and click Auto Clk to set the debugging communication speed. This scre...
Click Settings to open the Target Driver Setup dialog. Available configuration options are explained in Target Driver Settings section in µVision User's Guide.This site uses cookies to store information on your computer. By continuing to use our site, you consent to our cookies. If you are ...
Open the dialogOptions for Target — Debug, and insertconf_LPC17xx.iniinto theInitialization Filefield. Configure μVision to capture ETM trace data EnableUse, selectCortex-M/R J-LINK/J-Trace, and clickSettingsto open theTarget Driver Setupdialog. Click theTracetab. SetEnableandETM Trace Enable...
Chapter "Target interfaces and adapters" EL * Section "20-pin JTAG/SWD connector" updated. Chapter "RDI" added. Chapter "Setup" updated. Chapter "Device specifics" updated. AG Chapter "Working with J-Link" * Section "J-Link script files" updated. KN Chapter "Introduction" * Section "J-...
the Arm specific registers must not be written by the J-Trace probe before they have been clocked by a chip specific init. So doing the init via the target application would be way too late. The J-Link script makes sure everything is initialized at the correct time to avoid such issues...
I have a project that was built using IAR's Embedded Workbench. The target hardware contains an Nordic Semi nRF52832 from which only GND, Vcc, SWDIO and SWCLK are available on the outside. Flash and debug always worked flawlessly on this hardware using a
Using a J-Link script file is generally recommended, as otherwise the init section of the code will not be traced when initializing trace from the target application. Another benefit is that by using a J-Link Script file you guarantee that not debug code gets overlooked and accidentally stays...
specified,pleasecontactus.RevisionDateExplanation29070912SKChapter"Hardware",section"Targetboarddesign"updated.28070912SKChapter"Relatedsoftware":Section"J-LinkSTR91xCommander"added.Chapter"Devicespecifics":Section"STMicroelectronics"added.Section"TexasInstruments"added.Subsection"AT91SAM9"added.28070912AGChapter"...
73090701KN Chapter"Introduction" *Section"J-LinkandJ-Tracemodels"added *Sections"Modelcomparisonchart"& "J-Linkbundlecomparisonchart"added Chapter"J-LinkandJ-Tracemodels"removed Chapter"Hardware"renamedto "Targetinterfaces&adapters" *Section"JTAGIsolator"added Chapter"Targetinterfacesandadapters" *Section"...